Войти:
Оценок - 5, средний балл: 4.2 ( )

Инструкция по эксплуатации Heat & Glo LifeStyle, модель GEM42

Производитель: Heat & Glo LifeStyle
Размер: 1.26 mb
Название файла: 371_900.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Heat & Glo • GEM42 • 371-900 Rev. N • 2/05 Figure 26. Intermittent Pilot Ignition (IPI) Wiring Diagram NOTE 1: Ignition module, valve, pilot and wall switch operate on 3 volts. 120 VAC is required at junction box unless equipped with battery back-up. NEUTRAL GROUND REMOTE CONTROL HOT LOW VOLTAGE SEE NOTE 1 ON/OFFWALL SWITCH VALVE BROWN BROWN RED ORANGE GREEN BLACK OPTIONAL BATTERY BACK-UP ORANGE (IGNITOR) WHITE (SENSOR) BLACK GROUND TO FIREPLACE CHASSIS PILOT ASSEMBLY AND VALVE ASSEMBLY MUST BE GROUNDED (COMMON GROUND WITH FIREPLACE CHASSIS) SPARK TO PILOT IGNITOR IGNITOR MODULE 3V JUNCTION BOX TRANSFORMER 3V TRANSFORMER OUTLET PLUG-IN 3V TRANSFORMER FLAME SPARKER / SENSOR LOW VOLTAGE SEE NOTE 1 OPTIONAL BATTERY BACK-UP IGNITION MODULE (3V) ON/OFFSWITCH I S Figure 26. Intermittent Pilot Ignition (IPI) Wiring Diagram NOTE 1: Ignition module, valve, pilot and wall switch operate on 3 volts. 120 VAC is required at junction box unless equipped with battery back-up. NEUTRAL GROUND REMOTE CONTROL HOT LOW VOLTAGE SEE NOTE 1 ON/OFFWALL SWITCH VALVE BROWN BROWN RED ORANGE GREEN BLACK OPTIONAL BATTERY BACK-UP ORANGE (IGNITOR) WHITE (SENSOR) BLACK GROUND TO FIREPLACE CHASSIS PILOT ASSEMBLY AND VALVE ASSEMBLY MUST BE GROUNDED (COMMON GROUND WITH FIREPLACE CHASSIS) SPARK TO PILOT IGNITOR IGNITOR MODULE 3V JUNCTION BOX TRANSFORMER 3V TRANSFORMER OUTLET PLUG-IN 3V TRANSFORMER FLAME SPARKER / SENSOR LOW VOLTAGE SEE NOTE 1 OPTIONAL BATTERY BACK-UP IGNITION MODULE (3V) ON/OFFSWITCH I S Step 9. Wiring the Fireplace Intermittent Pilot Ignition (IPI) Wiring 3 Volt Transformer This appliance comes with a factory installed 3 volt transformer. Operation with Battery Back-up This appliance comes with a factory installed battery backup. Appliance Requirements This appliance requires that 110-120 VAC be wired to the factory installed junction box. Maintain correct polarity when wiring the junction box. ! WARNING: DO NOT CONNECT 110-120 VAC TO THE GAS CONTROL VALVE OR THE APPLIANCE WILL MALFUNCTION AND THE VALVE WILL BE DESTROYED. Optional Accessories Optional remote control kits require that 110-120 VAC be wired to the factory installed junction box before the fireplace is permanently installed. Heat-Zone and Heat-Out kits are approved with this fireplace as heat management accessories. Wall Switch Position the wall switch in the desired position on a wall. Run a maximum of 25 feet (7.8 m) or less length of 18 A.W.G. minimum wire and connect it to the fireplace ON/ OFF switch pigtails. ! WARNING: DO NOT CONNECT 110-120 VAC TO THE WALL SWITCH OR THE CONTROL VALVE WILL BE DESTROYED. CAUTION: LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICING CONTROLS. WIRING ERRORS CAN CAUSE IMPROPER AND DANGEROUS OPERATION. VERIFY PROPER OPERATION AFTER SERVICING. Heat & Glo • GEM42 • 371-900 Rev. N • 2/05 Heat & Glo • GEM42 • 371-900 Rev. N • 2/05 25 FINISH WALL MATERIAL MUST BE NON-COMBUSTIBLE - TOP AND SIDES 60” 52” NON-COMBUSTIBLE Step 10. Finishing Figure 28 shows the minimum vertical and corresponding maximum horizontal dimensions of fireplace mantels or other combustible projections above the top front edge of the fireplace. See Figures 2 and 3 for other fireplace clearances. Only non-combustible materials may be used to cover the black fireplace front. WARNING: WHEN FINISHING THE FIREPLACE, NEVER OBSTRUCT OR MODIFY THE AIR INLET/ OUTLET GRILLES IN ANY MANNER. ! Figure 28. Minimum Vertical and Maximum Horizontal Dimensions of Combustibles above Fireplace CAUTION: IF JOINTS BETWEEN THE FINISHED WALLS AND THE FIREPLACE SURROUND (TOP AND SIDES) ARE SEALED, A 300° F. MINIMUM SEALANT MATERIAL MUST BE USED. THESE JOINTS ARE NOT REQUIRED TO BE SEALED. ONLY NON-COMBUSTIBLE MATERIAL (USING 300° F. MINIMUM ADHESIVE, IF NEEDED) CAN BE APPLIED AS FACING TO THE FIREPLACE SURROUND. SEE THE DIAGRAM BELOW. Figure 29. Sealant Material Figure 27. Fan Wiring Diagram HIGH TEMPERATURE (3000F / 1490C MIN.) TOP & SIDES SEAL JOINT ! WARNING: A 8” minimum hearth extension is required to protect combustible floor construction in front of the fireplace. This hearth must be constructed of non-combustible material and extend the width of the fireplace. FAN SPEED CONTROL (RHEOSTAT) TEMPERATURE SENSOR SWITCH JUNCTION BOX .. .. CEILING COMBUSTIBLE SHEATHING 1 IN. TYPICAL 31 IN MINIMUM CLEARANCE FIREPLACE HEADER TOP FRONT EDGE OF FIREPLACE NON-COMBUSTIBLE SHEATHING TOP OF ARCH OPENING 17 IN. MINIMUM FROM TOP OF ARCH OPENING TO FIRST MANTEL PROJECTION 17 IN. MINIMUM NON-COMBUSTIBLE SHEATHING ABOVE FIREPLACE ARCH OPENING 1” 2” 3” 4” 5” 6” 7” 8” 10” 9” 11” 12” 26 Heat & Glo • GEM42 • 371-900 Rev. N • 2/05 Facing Requirements Facing Thickness from 3/4” to 1-1/4” Facing material within this thickness range can be brought to 1/2” behind the door top and sides. These non-combustible finishing materials must never overlap or obstruct the air outlet/inlet grille areas. Figure 30. Facing Thickness greater than 1-1/4” For facing material greater than 1-1/4” a template should be constr...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории