Производитель: Alto-Shaam
Размер: 4.56 mb
Название файла: MN-28641_BSC_Gas_0910.pdf
|
Фрагмент инструкции
Gas Fryer Operation & Care Manual • 2 Delivery 1 Unpacking 1 Safety Procedures and Precautions 2 Installation Installation Requirements 5-11 Dimension Drawings, weights & capacities 3-4 Clearance Requirements 5 Site Installation & Leveling 6 Ventilation 7 Gas Specifications 8 Gas Connection 9 Restraint Requirements - Mobile Equipment 10 Electrical Specifications 11 Operating Instructions Oil/Shortening Requirements 12 Controls Behind Access Panel 13 Boil-Out Instructions 14-15 Start-Up & General Operation 16 Cleaning & Maintenance 17 Oil Filtrations (For units with installed option) 18-21 Suggested Frying Times 22-23 Basic Control Operation 24-30 Service Service Troubleshooting 31-32 ASF-75G Service Views 34-38 ASF-60G Service Views 39-42 Wire Diagrams ASF-75G, 120V 43 ASF-75G, 230V 44 ASF-60G, 120V 45 ASF-60G, 230V 46 Warranty Transportation Damage and Claims Back Cover Limited Warranty Back Cover Gas Fryer Operation & Care Manual • 1 KEEP THIS MANUAL IN A CONVENIENT LOCATION FOR REFERENCE. Gas Fryer Operation & Care Manual • 1 INSTALLATION Gas Fryer Operation & Care Manual • 2 INSTALLATION Gas Fryer Operation & Care Manual • 2 INSTALLATION Gas Fryer Operation & Care Manual • 3 INSTALLATION ASF-75G SPECIFICATIONS DIMENSIONS exterior (h x w x d) ASF-75G without filtration or lifts 44-13/16” x 24-13/16” x 37-7/16” (1138mm x 629mm x 951mm) ASF-75G with filtration and lifts 44-13/16” x 24-13/16” x 38-11/16 (1138mm x 629mm x 983mm) basket dimensions (h x w x d) 6” x 9-3/16” x 14-3/16” (152mm x 232mm x 337mm) STANDARD ACCESSORIES Basket, Half-Size (2 included as standard) BS-27140 Brush Set (one 3-brush set included as standard) scrub brush BH-28693 straight brush BH-28691 Filter, Paper (7 paper filters included as standard) 7 count refill package FI-27791 100 count refill package FI-27794 CAPACITY SHORTENING/OIL: 73 lb (33 kg) maximum LOAD CAPACITY: 13 lb (6 kg) maximum OPTIONS Basket, Full-Size (48 chicken piece capacity) BS-26998 FILTERS Charcoal/Carbon (30 count pkg.) FI-27648 Reusable Mesh (single filter) FI-27014 Fry Pot Cover 5005136 Mobile Drawer Cover 5006073 Strainer/Skimmer CE-27400 Oil Discard Hose HO-27686 Banking Strip (1 strip req’d for every 2 banked fryers) 5008809 Mobile Oil Caddy TO-28359 Pre-filter Sieve Kit (for oil filtration system) 5010451 WEIGHT est. net weight: 360 lb (163 kg) ship weight: 520 lb (236 kg) carton dimensions: h x w x d 57” x 34” x 47” (1448mm x 864mm x 1194mm) ASF-75G WITH LIFTS AND FILTRATION 38-11/16" (983mm)OILTROLLEY50-3/16" (1274mm) LIFT UP44-13/16" (1138mm) LIFT DOWNElectricalGasConnection1/2" NPT24-13/16" (629mm) 31-9/16" (802mm) 12-7/16" (315mm) 2-7/8" (72mm) 31-13/16" (808mm)36-11/16" (931mm) 61-1/2" (1562mm)150° Gas Fryer Operation & Care Manual • 3 INSTALLATION ASF-60G SPECIFICATIONS STANDARD ACCESSORIES Basket, Half-Size (2 included as standard) BS-27963 Brush Set (one 3-brush set included as standard) scrub brush BH-28693 straight brush BH-28691 DIMENSIONS exterior (h x w x d) ASF-60G without basket lifts 44-3/4” x 15-3/4” x 33-5/8” (1136mm x 400mm x 853mm) ASF-60G with basket lifts 44-3/4” x 15-3/4” x 33-5/8” (1136mm x 400mm x 853mm) basket dimensions (h x w x d) 5-3/16” x 5-7/8” x 13-13/16” (131mm x 149mm x 328mm) OPTIONS Fry Pot Cover 5007596 Strainer/Skimmer CE-27400 Banking Strip (1 strip req’d for every 2 banked fryers) 1009367 Mobile Oil Caddy TO-28359 CAPACITY SHORTENING/OIL: 62 lb (28 kg) maximum LOAD CAPACITY: 8 lb (4 kg) maximum WEIGHT net weight: 248 lb (113 kg) ship weight: 330 lb (150 kg) est carton dimensions: 39” x 22” x 55” est h x w x d (991mm x 559mm x 1397mm) est ASF-60G WITH LIFTS 33-5/8" (853 mm) 23-3/8" (592mm) 47-1/2" (1206mm) 6-5/8" (168mm) 5-9/16" (141mm) Electric Connection31-9/16" (802mm)Gas Connection2-7/8" (72mm) 36-11/16" (931mm) 150. 15-3/4" (400mm) 44-3/4" (1136mm) 50-3/8" (1279mm) lift up Gas Fryer Operation & Care Manual • 4 INSTALLATION SITE INSTALLATION NOTE: To avoid equipment damage, remove the Mobile Oil Trolley before moving this appliance with a forklift or pallet lift. MINIMUM CLEARANCE REQUIREMENTS combustible non-combustible surfaces surfaces right side 0” (0mm) 0” (0mm) left side 0” (0mm) 0” (0mm) back 6” (152mm) 6” (152mm) front 25” (635mm) plus: 6” (152mm) minimum between the element swing in the extended position and the lower edge of the exhaust hood and filter media. entry clearance: 30” (762mm) uncrated Ne pas installer a une distance inferirure a celle indiquee ce-dessous d’une parol en matiere combustible: Cotes 6 pouches, Arriere 6 pouches. Gas Fryer Operation & Care Manual • 5 INSTALLATION SITE INSTALLATION 1. It is the responsibility of the installer to verify that this fryer installation is in compliance with the specifications listed in this manual and with local code requirements. 2. Hood installation is required. 3. Both cooking and cleaning functions require unobstructed access. The frypot, control panel, and front access door must be maintained free from obstruction. The access door must be access...
Эта инструкция также подходит к моделям:Фритюрницы - FRYTECH ASF-60G (4.56 mb)
Фритюрницы - FRYTECH ASF-60G (4.56 mb)
Фритюрницы - FRYTECH ASF-75G (4.56 mb)