Войти:
Оценок - 4, средний балл: 4.3 ( )

Инструкция по эксплуатации Heath Zenith, модель Hardwired Mechanical Chime 598-1223-01

Производитель: Heath Zenith
Размер: 516.77 kb
Название файла: 598-1223-01.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


1. Verify transformer power rating. Power must be supplied from a 16 Volt AC, 10 Watt or a 16 Volt AC, 15 Watt transformer. 2. Remove cover from existing chime. 3. Label all wires before disconnecting. Using masking tape, mark each wire according to existing chime terminal markings. • “F” – Front Push Button Wire • “T” – Transformer Wire • “R” – Rear Push Button Wire* 4. Disconnect all wires from existing chime. 5. Remove existing chime base from wall. 6. Determine proper chime base orientation. The chime cover style may determine orientation. 7. Determine cover mounting type. For hang pin and hole type covers, hang pin should be installed before mounting base to wall. Install hang pin by snapping into mounting hole or sliding onto chime base, depending on type of hang pin (see Figures 1 and 3). Illustrations may vary from actual chime unit. Figure 1 - Mechanical Chime Identification (Model 35 Base Shown) FRONTREARTRANSHang Pin, Snap-On Type (Used for Hang Pin and Hole Covers) Base Orientation Marking Wire Entrance Hole Mounting Slot (x4) Tone Bars Transformer and Push Button Wire Connections ContinuedPlungers Hang Pin Mounting Slot (Horizontal) Hang Pin Mounting Slot (Vertical) Hang Pin, Slide-On Type (Used for Hang Pin and Hole Covers) FRONTREARTRANSRTF8. Route wires through wire entrance hole in new chime base. 9. Mount chime base to wall using screws provided. 10. Connect wire “F” to screw terminal marked “FRONT”. Connect wire “T” to screw terminal marked “TRANS”. Connect wire “R” to screw terminal marked “REAR”* (See Figure 2). 11. Install chime cover (see page 4). *Note: Some installations may not include rear door push button. Figure 2 - Mechanical Chime Wiring (Model 35 Base Shown) Existing Chime Wires Wall Replacement Chime Base Rear Door Push Button (if Applicable) FRONTREARTRANSRTF8. Route wires through wire entrance hole in new chime base. 9. Mount chime base to wall using screws provided. 10. Connect wire “F” to screw terminal marked “FRONT”. Connect wire “T” to screw terminal marked “TRANS”. Connect wire “R” to screw terminal marked “REAR”* (See Figure 2). 11. Install chime cover (see page 4). *Note: Some installations may not include rear door push button. Figure 2 - Mechanical Chime Wiring (Model 35 Base Shown) Existing Chime Wires Wall Replacement Chime Base Rear Door Push Button (if Applicable) -3 -4 FRONTREARTRANSFigure 4 - Mounting Snap-On Cover install CHiMe CoveR Place chime cover securely over base. • For hang pin and hole covers: Attach hang pin to base prior to mounting base on wall. Line up hole in cover with pin and hang (see Figure 3). • For snap-on covers: Apply pressure to the cover until it snaps into place (see Figure 4). Firmly grasp cover and pull to remove from base. • For hang bracket covers: Determine if the cover will hang vertically or horizontally on the base. Place bracket into the correct slot inside chime cover. Adjust bracket (if necessary) so that bracket is flush with back surface of cover. Slide bracket into slot on base to hang cover (see Figure 5). Note: Never use cleaners or polishes. Never use any fluids on the chime mechanism. Use dry cloth to clean chime cover and base. TFigure 3 - Pin for Hanging Cover Hang Pin, Snap-On Type Illustrations may vary from actual chime unit. Snap-On Cover Base Orientation Marking Hang Pin, Slide-On Type FRONTUPTRANSFigure 5 - Mounting Hang Bracket Cover Illustrations may vary from actual chime unit. Hang Bracket Cover Base Orientation Marking Hang Bracket Chime Base (Mounted Vertically) Hang Bracket Slot FRONTUPTRANSFigure 5 - Mounting Hang Bracket Cover Illustrations may vary from actual chime unit. Hang Bracket Cover Base Orientation Marking Hang Bracket Chime Base (Mounted Vertically) Hang Bracket Slot -5 - tRoUBlesHootinG Chime does not sound: • Check Chime: Disconnect wire from terminal marked “TRANS”. Have someone operate push button at front door while you momentarily touch the “TRANS” wire to terminal marked “FRONT”. You will see a small spark if push button, wiring, and transformer are operating properly. Repeat the steps for “REAR” terminal and rear push button. If wiring between transformer and push button(s) check out properly, replace chime. • Check transformer: Test transformer voltage output with a volt meter. If a volt meter is not available, momentarily touch the two low-voltage terminals with a screwdriver. You will see a small spark if transformer is operating properly. If no spark is evident, replace transformer. • Check push Button(s): Remove suspected push button from door frame, disconnect wire from terminals and touch bare wires together. If chime operates, push button is defective. Replace push button. one YeaR liMiteD WaRRantY This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state or province to province. For a period of one year from the date of purchase, any malfunction caused by factory defective parts or workmanship will ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории