Войти:
Оценок - 2, средний балл: 4 ( )

Инструкция по эксплуатации Honeywell, модель Keypad Arming Station ELK-M1KPAS

Производитель: Honeywell
Размер: 180.78 kb
Название файла: el-m1kpas.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


It handles basic functionality and displays system status using 3 LEDs: Green for "Ready", Yellow for "Trouble", and Red for "Armed". The low cost and small footprint of the M1KPAS Arming Station makes it ideal for use as an alternative to the larger and more costly LCD keypads. It is particularly well suited for partitioned jobs such as an office, workshop, garage, etc., where full functionality is not necessarily required. The 12 button keypad is backlighted with blue LEDs and has quick arm keys for Exit (Away) and Stay. It also has a "F" key (function key) for use in in activating 1 of 6 programmable function operations. FEATURES • Blue/white Backlighted 12 button keypad • Access to six (6) Programmable Functions • Operates from the M1/EZ8 ’RS-485’ Data Bus • Built-in Piezo Mini Sounder • Quick arm keys for Exit and Stay • Flush mounts into a standard electrical box. ** • Utilizes a standard decorator style electrical cover plate (not included). SPECIFICATIONS • Connection: 4 Pin Plug-in "Flying Lead" Connector (Included) • Color: White • Operating Voltage: 13.8 VDC • Current Draw: Less than 30 mA with min. activity - 44 mA fully active • Size: 4.658" W x 5.5" H x .95" D (.375" D with recess mount) Features and Specifications subject to change without notice. ** The local AHJ (authority having jurisdiction) or State and local regulations may prohibit the installation of a M1KPAS Arming Station into an electrical box together with any high voltage circuits. In some cases a special dual voltage box or divider partition (separator) may be successfully used. One known manufacturer of these is "Carlon". Visit your local home center or electrical supply company for availability. Elk specifically warns against improper use, particularly unauthorized installation or servicing in conjunction with high voltage circuits except by licensed and qualified high voltage personnel. Elk is not responsible for damages or harmful consequences. Always consult the local AHJ and follow state and local regulations. In some cases the best solution is to install the M1KPAS into a separate and dedicated single gang box. PO Box 100 . Hildebran, NC 28637 USA . 828-397-4200 Voice . 828-397-4415 Fax . email: info@elkproducts.com L610 08/24/06 Page 1 INSTALLATION OF ELK-M1KPAS KEYPAD ARMING STATION The M1KPAS mounts into a standard electrical box. Depending upon local/state regulations it may be permissible to mount an M1KAS alongside other electrical devices provided that a special low voltage divider insert and/or low voltage combo box is utlized. Select a location with an ambient temperature range between 32° and 120° F (0° to +49° C). Avoid direct sunlight if possible. CAT5 or CAT6 wire (4 pair, 8 conductor) is highly recommended for all data bus cables and the extra wires may be required for data return paths where multiple homeruns or devices are installed. NOTE: Please refer to the M1 or EZ8 Installation Manual for important information about Data Bus termination when multiple homerun cables are installed. Minimum conductor size is 22 or 24 gauge. Maximum resistance per wire is 25 Ohms. Device placement beyond 1000’ is not recommended. DO NOT SPLICE OR CONNECT WIRES WITH THE CONTROL POWER ON. 1. Turn off all power to the control. 2. Splice the Black, Red, White, and Green wires of the 4-wire cable assembly to the data bus wires. Plug the connector onto the back of the M1KPAS. Tuck the wires and splices neatly into electrical box. 3. Fasten the top and bottom mounting ears to the electrical box using flat head #6 machine screws. 4. Turn on the power to the control. One or more of the lights on the M1KAS may be illuminated indicating the unit has power, however it will not become operation until it has been assigned an address and has been enrolled into the Control. See steps on next page. Hookup Diagram for M1KPAS Keypad Arming Station (see M1/EZ8 Instruction Manuals for multiple Keypad hookups.) Splice wires from data bus cable to Keypad assembly using ELK-900-2 "B" Connectors. ELK-M1KPAS BLACK WHITE GREEN RED ELK-WO40A 4 Wire Keypad Cable Assembly Data Bus Cable CAT5 or CAT6 Recommended Pin 1 4 To Control NEG - DATA B +12V DATA BUS +VKP DATA B DATA A NEG EGND J1J2 RE: Data Bus Termination Note DATA BUS TERMINATION IS VERY IMPORTANT!! Ideal setup is 2 home run cables with daisy chained devices. The lastdevice on each cable MUST have a terminating resistor installed (activated) via the 2 pin header/jumpers marked JP1 on M1KPAS & M1KP2 Keypads and expanders, JP2 on M1KP Keypads. Place a black shorting cap from hardware pack onto the 2 pins to install a 120 Ohm resistor across data lines A & B. NOTE: Place a shorting cap on JP3 of Main Board if there is only 1 data bus cable. See diagrams on multiple cables. Temporary Connection "Plug-in" jacks for RS-485 Data Bus (J1 & J2) Local connection for Data Bus Devices ie: Keypads, etc. for testing purposes only. BLACK WHITE GREEN RS-485 Data Bus (Max. length is ...

Эта инструкция также подходит к моделям:
Двери и окна - Keypad Arming Station ELK-M1KPAS (180.78 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории