Войти:
Оценок - 1, средний балл: 3 ( )

Инструкция по эксплуатации Lennox Hearth, модель LBF 36LBF

Производитель: Lennox Hearth
Размер: 467.42 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Step 7. Position the center clip as shown in Figure 5, below, and attach it using the two (2) provided screws. Step 8. Proceed to bi-fold door installation procedures on the next page. (Detail: Installation of left air deflector.) (Detail: Installation of center clip on top of both air deflectors. Figure 3: Installation of Air Deflectors and Center Clip on 36LBF/LBF-BS and 42LBF/LBF-BS (Detail) Figure 5: Installation of Center Clip on 50LBF/LBF-BS LENNOX HEARTH PRODUCTS • LBF SERIES BI-FOLD GLASS DOORS • INSTALLATION INSTRUCTIONS 3 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE INSTALLING THE BI-FOLD DOORS Step 1. Refer to Figure 1 on page 1 for correct door position. Starting with the left door panel, hold it at a slight angle to the door frame outer edge, with the top of the door tilted toward the center of the firebox. Step 2. Swing the lower outer corner of the door over the hole in the lower frame of the firebox opening, and insert the lower pivot pin into the hole (Figures 6 and 7, below). ALIGNING THE BI-FOLD DOORS The doors are properly aligned when the top door trim is in a straight, level line, and the vertical gap between the doors is even from top to bottom. To align the bi-fold doors: Step 1. Grasp one door handle, and loosen the lower door pivot pin using a 3/8" open-end wrench. Note: The upper door pivot pins can be loosened for adjustment purposes; however, it is easier to loosen the lower pins. Step 2. Slide the door panel on the hinge pin until the gap between the upper door trim and upper frame is even. Step 3. Retighten the lower door pivot pin. Step 4. If needed, repeat this procedure for the opposite door. LowerPivot Pin PivotPointLowerFramePivot PinRoller PinLock GENERAL OPERATING PRECAUTIONS AND INSTRUCTIONS Figure 6: Lower Left Door Panel CAUTION THESE GLASS DOORS ARE LISTED ONLY FOR USE WITH FIREPLACES OR APPLIANCES THAT SPECIFY LBF SERIES BI-FOLD GLASS DOORS. USE ON ANY OTHER FIREPLACE OR APPLIANCE MAY CONSTITUTE A POTENTIAL FIRE HAZARD. • Avoid building extremely large fires, as the tempered glass could become damaged. • Use fireplace tools carefully to avoid striking the glass. • Keep wire mesh screens closed during fireplace use. • Fireplace flue damper must remain open until fire is completely out. • Ensure that wood and embers are well within the confines of the grate area and well away from the glass doors. • Keep wire mesh screens closed during fireplace use. • Keep glass doors closed at night when retiring to minimize the loss of heated room air up the vent. IMPORTANT: THE FINISH OF THESE DOORS MAY BE PROTECTED WITH A SELF-ADHERING PLASTIC COATING THAT MUST BE REMOVED BEFORE HEAT IS GENERATED BY A FIRE IN THE FIREBOX. TO PREVENT MELTING, ENSURE THAT ANY PLASTIC COATING PROTECTING THE FINISH OF THESE DOORS IS REMOVED FOLLOWING INSTALLATION. REFER TO THE FIREPLACE INSTALLATION INSTRUCTIONS AND HOMEOWNER'S CARE AND OPERATION INSTRUCTIONS FOR DETAILED INSTRUCTIONS REGARDING THE MAINTENANCE OF THE FINISH OF THESE DO...

Эта инструкция также подходит к моделям:
Двери и окна - LBF 50LBF (467.42 kb)
Двери и окна - LBF LBF-BB (467.42 kb)
Двери и окна - LBF LBF-BS (467.42 kb)
Двери и окна - LBF 38LBF (467.42 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории