Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Assa, модель ELECTRIC LOCK

Производитель: Assa
Размер: 312.01 kb
Название файла: 6ebf17c1-73b8-4b16-8ff7-d586c22d71e1.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


A.1, 10/99 SECURITRON MODEL LCP SERIES ELECTRIC LOCK CONTROL PANEL TABLE OF CONTENTS AND GUIDE TO THIS MANUAL The LCP series is a powerful and versatile system with many standard and optional features. You will generally use only some of these features so this table of contents includes a description of the type of application that applies to each different section. By studying it first, you can save considerable time by skipping over those parts of the manual that don't apply. SECTION 1. DESCRIPTION --------------------------------------------------------------------Page 1 SECTION 1.1 GENERAL ------------------------------------------------------------------------Page 1 This section explains part numbering and allows you to determine your panel configuration. SECTION 1.2 PANEL POWER-----------------------------------------------------------------Page 1 SECTION 1.3 LOCK CONTROL ---------------------------------------------------------------Page 2 SECTION 1.4 MONITORING--------------------------------------------------------------------Page 2 SECTION 1.5 AUDIBLE ALARM AND ALARM RESET---------------------------------Page 3 The above 4 vital sections contain information that applies to any LCP series panel. SECTION 2. OPTIONS ---------------------------------------------------------------------------Page 4 Once you have determined the options present or desired on your panel, read the corresponding section below to learn the function and operation of the supplied option. SECTION 2.1 SILENCE LATCH (OPTION "SL") -----------------------------------------Page 4 SECTION 2.2 EMERGENCY RELEASE (OPTION "PB")-------------------------------Page 4 SECTION 2.3 ADDITIONAL MONITORING LIGHTS (OPTION "AM") --------------Page 4 SECTION 2.4 SWITCH BYPASS KEYSWITCH ("KP1", "KP2" "MK1", "MK2") -Page 5 SECTION 2.5 MOMENTARY SWITCHES (OPTION "MOM")--------------------------Page 5 SECTION 2.6 HIGH VOLUME PUSH BUTTONS (OPTION "HT")--------------------Page 5 SECTION 3. BOARD TERMINAL DESCRIPTIONS --------------------------------------Page 6 This is a reference section. It starts with a drawing showing all terminals on the panel board and then describes the meaning and function of each. Reading the section explains the capabilities of the panel, but it's not necessary to complete an installation. As a reference, the section is of great help in answering questions which arise or planning unusual uses. SECTION 4. WIRING------------------------------------------------------------------------------Page 7 SECTION 4.1 POWER INPUT WIRING ------------------------------------------------------Page 7 The above section should be read for all installations. SECTION 4.2 FAIL SAFE LOCKS ------------------------------------------------------------Page 9 If the locks you will be using are fail safe (secure when powered), this section should be carefully read to determine the proper hookup. Figure 3 (Page 10) shows the severaldifferent ways that fail safe locks may be connected to the panel. © Copyright, 1999, all rights reserved • Securitron Magnalock Corp., 550 Vista Blvd., Sparks NV 89434, USA Tel: (775) 355-5625 • (800) MAGLOCK • Fax: (775) 355-5636 • Website: An ASSA ABLOY Group company Rev. A.1, 10/99 SECTION 4.3 FAIL SECURE LOCKS --------------------------------------------------------Page 10 If the locks you will be using are fail secure (secure when not powered), this section should be carefully read to determine the proper hookup. Figure 4 (Page 12) shows the severaldifferent ways that fail secure locks may be connected to the panel. SECTION 4.4 POWERED SWITCHING DEVICES AT THE DOORS ----------------Page 14 Read this section if your are using a switching device at the door which employs power such as a digital keypad or card reader. SECTION 4.5 WIRING UNUSED ZONES ---------------------------------------------------Page 15 If any zones are not connected to locks, read this section. SECTION 4.6 WIRING WITH RELEASE HOLD TIMER ---------------------------------Page 15 If the locks include a momentary switch for entry or exit which activates a timer to release the door for an interval, this section shows preferred wiring techniques. SECTION 4.7 REMOTE INDICATOR WIRING ---------------------------------------------Page 16 If controls at the door such as push buttons or keyswitches include indicator lights, this section advises methods of wiring them for clear prompting to individuals using the door. SECTION 4.8 AC LOCK CONTROL ----------------------------------------------------------Page 17 This section explains use of the panel with AC locks. SECTION 5. OPTION WIRING -----------------------------------------------------------------Page 17 The following 5 sections explain the field wiring that relates to the options which may be supplied with the panel. In the case of certain options, it is possible that the option be added in the field by the installer if it ought to have been ordered but was not. Therefore, read the appropriate ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории