Войти:
Оценок - 3, средний балл: 4.7 ( )

Инструкция по эксплуатации Black & Decker, модель 9000

Производитель: Black & Decker
Размер: 555.48 kb
Название файла: 3c0766c3-4018-4013-b61f-88a8fb8bed42.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Basic Components 3 A. Plug-In Modules 4 · Scanning Module 4 · Contact Module 4 B. Pistol Grip Housing 4 · Display Panel 4 · Trigger On/Off Switch 5 · I/O Port 5 · Battery Compartment/Battery 5 · Wrist Strap 5 · Sensitivity Control Dial 5 · Storage Entry Button 5 · Head Set Jack 5 · Recharge Jack 5 3. Accessories 6 A. Standard Accessories 6 · Headset 6 · WTG-1 Warble Tone Generator 6 · Rubber Focusing Probe 6 · Stethoscope Extension Kit 6 · 5PC-C9 I/O Cable 6 · BCH-9 Battery Charger 6 · BCH-WTG Battery Charger 6 B. Optional Accessories 6 · LRM-9 6 · CFM-9 6 · UWC-9000 6 · DHC-2HH Hard Hat Headphones 6 · DHC 1991 Ear Piece 6 · SA-2000 Speaker Amplifier 6 · UFMTG-1991 7 · WTG-2SP Warble Pipe Threaded Tone Generator 7 · BP-9 7 · BPA-9 7 · BCH-92 7 · BCH-WTG2 7 · HTS-2 7 · SHEATH 7 · LLA 7 · 5PC-MP 7 · 5PC-BNC 7 · QCH-9 7 · QCH-92 7 1 4. Operation Mode 8 · Display Panel 8 · Bar Graph Display 8 · Sensitivity Control Dial 8 · Sensitivity / Volume Adjust 8 · Frequency Adjust 9 · Yellow Store Button 9 · Store a Reading 9 · Overwrite Data or Enter Data In a New Location 9 · Text Editor 10 5. Setup Mode 10 · Data Transfer 10 · Set Time & Date 11 · dB Scale Select 11 · dB Offset Val(Value) (This is a Reference dB Level) 12 · Display Mode 12 · Calibration Due Date 13 · Text Editor 13 · Factory Defaults 13 · Exit To Program 14 6. User Instructions 14 · Trisonic- Scanning Module 14 · Method of Airborne Detection 14 · Headset 14 · Rubber Focusing Probe 14 · Stethoscope Module 14 · Stethoscope Extension Kit 14 · Charging The UP9000 14 · Warble Tone Generator 15 · Charging The Warble Tone Generator 15 · Helpful Hints 15 · Auto Shutdown Battery Feature 15 · Resetting The On Board Computer 15 7. Applications Leak Detection, How to Locate Leaks, Shielding Techniques, Low Level Leaks 16-18 Tone Test (Ultratone) 18-19 Electric Arc, Corona, Tracking Detection 20-21 Monitoring Bearing Wear 21 Detecting Bearing Failure 22 Comparative & Historical Testing 22 Lack of Lubrication 23 Over Lubrication 23 Slow Speed Bearings 23 FFT Interface 23 General Mechanical Trouble Shooting 24 Locating Faulty Steam Traps 25 Traps: Inverted Bucket, Float & Thermostatic, Thermodynamic, Thermostatic 26 Inspecting Valves 27 ABCD Method 28 Leakage Behind Walls 29 Partial Blockage 29 Flow Direction 29 Ultrasound Technology 30 Instructions for Setting Combination Lock On Carrying Case 31 2 WELCOME TO THE WONDERFUL WORLD OF AIRBORNE ULTRASOUND INSPECTION Congratulations, you are about to experience the ultimate in airborne/structure borne ultrasonic inspection. Your Ultraprobe 9000 is equipped with features that will help you inspect in the most challenging environment. 1. OVERVIEW Your Ultraprobe 9000 is a versatile instrument with many features that will make your inspections easy, fast and accurate. As with any new instrument, it is important to review this manual before you begin inspections. While simple to use as a basic inspection tool, there are many powerful features that when understood, will open up a world of opportunities for inspection and data analysis. ULTRASOUND TECHNOLOGY INSTRUCTION SCHOLARSHIP CERTIFICATE: Your Ultraprobe 9000 has many applications ranging from leak detection to mechanical inspection and may be used to trend, analyze or just find a problem. How it is used is up to you. As you gain knowledge and learn how many modes of inspection you can cover, you might want to extend your knowledge by enrolling in one of the many training courses offered by UE Training Systems, Inc. A Scholarship certificate is available to you. Simply fill out the form found at the end of this manual and mail or fax it in. The Ultraprobe 9000 is an ultrasonic inspection information, storage and retrieval system in a pistol housing. There are two modes that are important to understand: OPERATION MODE: The operation mode will be described in detail under the operation mode section. In this mode you will perform all inspection actions such as scanning, probing, “Click and Spin” activities, and store data. NOTE: “Click” operations require pressing a dial. “Spin” operations require turning a dial. SET UP MODE: The setup mode will be described in detail under the Set Up Mode section,. There are 9 menu options that will be described in that section. 2. BASIC COMPONENTS Trisonic Scanning Module Headphones Pistol-Grip Housing Short “Stubby ” 1” Probe Stethoscope Extension Kit Stethoscope Module Rechargers (2) Wrist Strap WTG-1 Warble Tone Generator I/O Cable Rubber Focusing Probe 3 Trisonic Scanning Module Stethoscope Module A. PLUG-IN MODULES TRISONICTM SCANNING MODULE: This module is utilized to receive air-borne ultrasound such as the ultrasounds emitted by pressure/vacuum leaks and electrical discharges. There are four prongs at the rear of the module. For placement, align the prongs with the four corresponding jacks in the front end of the pistol housing and plug in. The TrisonicTM Scanning Module has a phased array of three piezoelectric transducers to pi...

Эта инструкция также подходит к моделям:
Дрели и шуропопверты - 9000 (555.48 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории