Войти:
Оценок - 6, средний балл: 4.2 ( )

Инструкция по эксплуатации Panasonic, модель EYFLA1A

Производитель: Panasonic
Размер: 2.14 mb
Название файла: e806b0db-272d-473c-8254-9c940173446d.pdf
Язык инструкции:enesfr
Перейти к скачиванию



Фрагмент инструкции


• The tightening torque value and precision vary with factors such as the material into which the bolt is being driven and the condition of the socket being used. Adjust the torque as necessary for the work being performed. Bolt tightening torque varies due to the factors described below. 1) Bolt • Bolt diameter: Tightening torque generally increases with bolt diameter. • Torque coefficient (indicated by the bolt manufacturer), grade, length, etc. -9 ) Other • Bit and socket condition: Material, amount of play, etc. • Use of a universal joint or socket adapter • User: Manner in which the tool is applied to the bolt, strength with which the tool is held, manner in which the tool’s switch is engaged • Condition of object being tightened: Material, seating surface finish Setting the tool to configuration mode 1. Turn off the control panel. • If the control panel is on, remove and then reinsert the battery pack. . Engage the switch while pushing the button and then release both the button and the switch. • After all the LED lamps have turned off, the control panel will flash and change to configuration mode. NOTE: • Tools ship from the factory set to “F” mode (torque control function off). • The control panel will turn off if the tool is not operated for a period of 5 minutes. Configuring the torque clutch setting (1) ( ) Display Battery indication lamp 1. Press the and buttons to select the clutch setting that is appropriate for the work being performed. As the button As the button is pressed is pressed 29 30 F 12 28 … 3 • “F” indicates that the torque control function is off. -10 • You can select from 30 torque clutch settings (1 to 30). • Use figures from the Tightening Torque Chart to guide your selection of torque clutch setting. (See the following tightening torque chart) . Press the OK button to accept the selected torque clutch setting. • The control panel will stop flashing and light up. CAUTION: • You must press the OK button in order for the selected setting to take effect. • Be sure to verify the new value after changing the setting. (See page 11.) Tightening Torque Chart (for Reference Use) The values illustrated on this chart were measured under the conditions described below and are provided for reference purposes. Actual tightening torque varies with ambient conditions (the particular bolt being tightened, hardware being used, method of holding the bolt in place, etc.). 0 10 20 30 40 50 60 EYFLA1 (M6) EYFLA2 (M6) EYFLA1 (M8) EYFLA2 (M8) EYFLA3 (M8) EYFLA3 (M10) N • m 1 2 3 4 5 6 7 8 9 101112131415161718192021222324252627282930 Measurement conditions • Temperature: Room temperature ( 0°C/68°F) Using the Interval Set • The interval set operates to prevent the tool from operating after it automatically stops as a result of the torque control function, even if the switch is engaged. 1. Set the tool to configuration mode. (See page 10.) . Press the interval set button. • The control panel will begin flashing. Display: The number 0 flashes on and off. Battery indication lamp: The middle bar of the battery flashes on and off. Display Battery indication lamp 3. Press the and buttons to set the desired time. Buttons Display Seconds 30 3 1 0.1 0 Off 4. Press the OK button to accept the selected setting. • The control panel will stop flashing and light up, and the torque clutch setting will be displayed. CAUTION: • Be sure to verify the new value after changing the setting. Initializing All Settings Factory settings • Torque clutch setting: “F” (torque control function off) • Interval setting: 0 (off) • This section explains how to revert all tool settings to their default values at the time of shipment from the factory. • The error display will be turned off. 1. Set the tool to configuration mode. (See page 10.) . Press the format button. • The control panel will begin flashing. Display: The letter “F” flashes on and off. Battery indication lamp: The upper and lower bars of the battery flash on and off. Display Battery indication lamp - 11 3. Press the OK button to accept the selected setting. • The control panel will stop flashing and light up. Checking Tool Settings • This section describes how to have the tool display current settings for approximately 3 seconds when the tool is stopped. • You cannot check tool settings when the control panel is turned off. First, engage the switch briefly to reactivate the display. Checking the torque clutch setting 1. Press the torque set button. • Control panel display Display: The torque set lights up. Battery indication lamp: The upper bar of the battery flashes on and off. Checking the interval 1. Press the interval set button. • Control panel display Display: The interval set lights up. Battery indication lamp: The middle bar of the battery flashes on and off. Checking tool circuits 1. Press the torque set button. • Control panel display Display: The torque set display lights up. Battery indication lamp: The middle and lower bars of the battery flash on and off....

Эта инструкция также подходит к моделям:
Дрели и шуропопверты - EYFLA2Q (2.14 mb)
Дрели и шуропопверты - EYFLA2A (2.14 mb)
Дрели и шуропопверты - EYFLA3J (2.14 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории