Войти:
Оценок - 2, средний балл: 4.5 ( )

Инструкция по эксплуатации Panasonic, модель EY7540

Производитель: Panasonic
Размер: 1.71 mb
Название файла: EY7540-MULTI.pdf
Язык инструкции:enesfr
Перейти к скачиванию



К этому устройству также есть другие инструкции:

Фрагмент инструкции


• Charging will not start if the battery pack is warm (for example, immediately after heavy-duty operation). The orange standby lamp will be flashing until the battery cools down. Charging will then begin automatically. 4. The charge lamp (green) will flash slowly once the battery is approximately 80% charged. 5. When charging is completed, the charging lamp will start flashing quickly in green color. 6. If the temperature of the batter pack is 0°C or less, charging takes longer to fully charge the battery pack than the standard charging time. Even when the battery is fully charged, it will have approximately 50% of the power of a fully charged battery at normal operating temperature. 7. If the power lamp does not light immediately after the charger is plugged in, or if after the standard charging time the charging lamp does not flash quickly in green, consult an authorized dealer. 8. If a fully charged battery pack is inserted into the charger again, the charging lamp lights up. After several minutes, the charging lamp may flash quickly to indicate the charging is completed. NiMH/ NiCd Battery Pack NOTE: When you charge the battery pack for the first time, or after prolonged storage, charge it for about 4 hours to bring the battery up to full capacity. -10 Battery charger (EY0L80) 1. Plug the charger into the AC outlet. NOTE: Sparks may be produced when the plug is inserted into the AC power supply, but this is not a problem in terms of safety. . Insert the battery pack firmly into the charger. 3. During charging, the charging lamp will be lit. When charging is completed, an internal electronic switch will automatically be triggered to prevent overcharging. LAMP INDICATIONS • Charging will not start if the battery pack is warm (for example, immediately after heavy-duty operation). The orange standby lamp will be flashing until the battery cools down. Charging will then begin automatically. 4. When charging is completed, the charging lamp will start flashing quickly in green color. 5. If the charging lamp does not light immediately after the charger is plugged in, or if after the standard charging time the charging lamp does not flash quickly in green, consult an authorized dealer. 6. If a fully charged battery pack is inserted into the charger again, the charging lamp lights up. After several minutes, the charging lamp may flash quickly to indicate the charging is completed. Green Lit Charger is plugged into the AC outlet. Ready to charge. Green Flashing Quickly Charging is completed. (Full charge.) Green Flashing Battery is approximately 80% charged (Usable charge. Li-ion only). Green Lit Now charging Orange Lit Battery pack is cool. The battery pack is being charged slowly to reduce the load on the battery. (Li-ion only) Orange Flashing Battery pack is warm. Charging will begin when temperature of battery pack drops. If the temperature of the battery pack is -10°C or less, the charging status lamp (orange) will also start flashing. Charging will begin when the temperature of the battery pack goes up (Li-ion only). Charging Status Lamp Left: green Right: orange will be displayed. Both Orange and Green Flashing Quickly Charging is not possible. Clogged with dust or malfunction of the battery pack. - 11 M10 x 35 mm. M1 , M14, M16 x 45 mm N . m Standard bolt N . m Standard bolt VI. MAINTENANCE Use only a dry, soft cloth for wiping the unit. (kgf-cm) Do not use a damp cloth, thinner, benzine, 196.0 or other volatile solvents for cleaning. (2000) M16 M14 M12 M10 VII.TIGHTENING TORQUE The power required for tightening a bolt will vary, according to bolt material and size, as well as the material being bolted. Choose the length of tightening time accordingly. Tightening torque 147.0 (1500) 98.0 (1000) 49.0 (500) Reference values are provided below. (They may vary according to tightening conditions.) Factors Affecting Tightening Torque The tightening torque is affected by a wide variety of factors including the followings. After tightening, always check the torque with a torque wrench. 1) Voltage When the battery pack becomes nearly discharged, the voltage decreases and the tightening torque drops. Bolt Tightening Conditions M8, M10 x 35 mm. M1 x 45 mm High tensile bolt N . m (kgf-cm) (Bolt size: Millimeters) 147.0 (1500) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 Tightening time (Sec.) Washer Bolt Steel platethickness10 mm (3/8") Washer Nut Spring washer Tightening conditions • The following bolts are used. Standard bolts: Strength type 4.8 High tensile type 1 .9 Explanation of the strength type 4.8 Bolt yield point (80% of tensile strength) 3 kgf/mm (45000psi) Bolt tensile strength 40 kgf/mm (56000psi) M12 M10 M8 Tightening torque 98.0 (1000) ) Tightening time Longer tightening time results in increased tightening torque. Excessive tightening, however, adds no value and reduces the life of the tool. 3) Different bolt diameters 49.0 (500) 0.0 0.5 1.0 1.5 2.0 2.5 3.0 The size of the bolt diameter affects the Tightening time (Se...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории