Войти:
Оценок - 3, средний балл: 3 ( )

Инструкция по эксплуатации Fishman, модель AIRFREE LDS9000

Производитель: Fishman
Размер: 602.83 kb
Название файла: 23464c67-d5c6-471a-b076-aaf0c684b41a.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


Our 9000-line of AirFree dispensers uses a patented positive displacement technology to provide the highest level of repeatability of any dispenser utilizing a syringe as a reservoir. We guarantee it. Please spend a few moments familiarizing yourself with the LDS9000 dispenser. Our recommended testing procedures provide an interactive tutorial on the dispenser’s functions. When complete, review the helpful information we have included based on our 40 years of dispensing experience. After completing the guide, should you have any additional questions please don’t hesitate to contact Fishman or your authorized Fishman dealer. US & Canada: 800-433-2115 United Kingdom: 1285 644211 Worldwide: 1-508-435-2115 The Fishman Promise We promise that our products will operate to your complete satisfaction. We strive for the highest standards regarding quality, workmanship and attention to detail. If for any reason you feel that you are not satisfied with our products or support, I extend the offer to write or call me personally. Our interest is to build partnerships through understanding your needs and incorporating them into our products and services.Your trust in Fishman is our ultimate reward. Scott Beebe, President of Fishman Corp. Table of Contents Page Getting Started.............................................................................................4 Specifications ...............................................................................................5 Operation.....................................................................................................6 Program Control ..........................................................................................7 How to Use the Control Panel.....................................................................8 LDS9000 Gun Assembly ...........................................................................10 Attaching the Syringe ................................................................................11 Removing the Syringe................................................................................13 Program Function.......................................................................................14 How to Make a Bead .................................................................................17 Operating Tips ...........................................................................................18 Loading the Reservoirs...............................................................................20 Alternative Filling Methods .......................................................................21 Defining the System...................................................................................22 How the LDS9000 Works .........................................................................26 Troubleshooting..........................................................................................27 Glossary......................................................................................................28 Accessories .................................................................................................30 Dispenser Component Selector Guide ......................................................31 Two Year Fault Free Warranty....................................................................32 Meets applicable CSA and CE requirements. This manual is for the express and sole use of Fishman dispenser users and purchasers, and no portion of this manual may be reproduced in any form. Fishman, AirFree, AirPulse, PosiLok, FreeFlow, SafeLok and DripFree are trademarks of Fishman Corporation. © 2004 Fishman Corporation Getting Started This manual contains all the information you will need to set up and test the 9000 series AirPulseTM dispensers. • You will find the hook up for the LDAV on pages 10-15. For the MDAV, review 16-19. For the SDAV review 20-23. • Next, pages 24-25 will show your how to set up and test a thick paste-like material. • Finally, pages 26-27 explain how to dispense watery fluids using vacuum control. The remainder of the manual applies to all 9000 series AirFreeTM dispensers. First Steps 3 2 1 Unpack the shipping box and use the supplied checklist to assure all items are present. If an item is missing, please contact us immediately. Make sure the set up area has access to power. No compressed air will be needed. You are about to experience the world’s only AirFreeTM fluid dispenser. No compressors, no filtration, no plumbing. Activate your extended two (2) year no-fault warranty by following the instructions in the enclosed “On Line Warranty” letter to activate online. Once your dispenser is set up, return to this section to familiarize yourself with the multiple functions of the program controls. Specifications Input Voltage: Input Voltage: 100-240 VAC 47-63Hz Max Inrush Current: 3.2A/1.8A Output Voltage: 5.0VDC Output Power: 4.6W Fuse Rating: 1.0A/250 VAC Initiate Circuit: Foot Ped...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории