4 Specifications Electrical Each icemaker and dispenser require a separate circuit with with electrical disconnect within 10 ft (6m). Equipment ground required. Standard electrical – 115V, 60Hz, 1 phase. Maximum dispenser fuse – 15 amps, Maximum icemaker fuse – 20 amps each. Model Icemaker Dispensernumber amperage amperage VU155K series 11.0 amps ea 8.7 amps Plumbing Dispenser 3/4" PVC pipe nipple for bin drain 3/4" PVC pipe nipple for drain pan drain 1" ID hose for beverage bath drain Beverage connections 1/4" ID syrup beverage hose 3/8" 45° flair fitting for water inlet 1/4" ID CO2 3/8" ID plain water inlet Note: Set CO2 pressure to 75 psi and syrup pressure to 60 psi. Drains should be hard piped and insulated. Maintain at least 1/4" per foot (6mm per 304mm run) slope on drain line run. Water disconnect within 10 feet (3m) of dispenser is suggested for automatic load units. Follett recommends use of a Follett model AFSYSTMFL4S water filter on icemakers connected to automatic fill dispensers. Icemaker Refer to detailed specifications in icemaker installation manual packed with icemaker 5 Dimensions and clearances Required clearances 51" (1295mm) minimum above counter for installation if dispenser will be dropped into counter 36" (915mm) minimum above counter for all units after installation for auger cleaning and servicing 12" (305mm) minimum on side opposite ice chute for service 12" (305mm) minimum on ice chute side if ice transport tube enters this side 12" (305mm) minimum between dispenser side(s) and optional icemaker(s) Front View 37.25" (947mm) (10 valve unit) 31.25" (794mm) (8 valve unit) carbonation pump *DO NOT CONNECT TO DRAIN SYSTEM 6" min 27.375" (696mm) ice transport Side View tube entrance 6" (153mm) 25.8" (656mm) 8.75" 3/4 PVCslip joint drain 3/4 PVC slip joint drain 18.5" (470mm) beverage waterbath overflow beverage drain pan drain 3.5" (889mm) 17" (432 mm) 18.875" (479mm) 18.875" (479mm) beverage line air break* electrical connections 21.75" (553mm) 28" (712mm) counter top ice transport tube 49.75" (1264mm) 12" min Manual load unit Dispenser with 1 optional auto-fill icemaker kit(s) Dispenser with 2 optional auto-fill icemaker kit(s) (223mm) power bin signal 6 Installation Installing dispenser in counter Note: All dispensers must be supported from below with supplied 6" – 9" (153 – 229mm) adjustable leg accessory, or equivalent. Do not hang dispenser on flange. All dispensers must be installed level in both directions to ensure proper operation. 1. Check that dispenser location meets all requirements in this manual and cut counter as shown. Plan View Plan View units with up to 8 valves units with 10 valves counter cut-out counter cut-out +.125" - .125"30.375" (772mm) +3 mm - 3 mm 26.25" +.125" - .125" +.125" - .125" 36.375" (924mm) +3 mm - 3 mm (667mm) +3 mm - 3 mm 26.25" +.125" - .125" (667mm) +3 mm - 3 mm Front of counter Front of counter 2. Place support blocks in cabinet to raise dispenser to a height of 12" (305mm). 3. Place dispenser in counter onto support blocks. 4. Attach adjustable legs to dispenser. 5. Remove support blocks and lower dispenser feet to floor. 6. Adjust legs for 1/8" (4mm) clearance between dispenser lip and countertop to verify there is no load on flange. 7. Apply a bead approximately 1/4" (6mm) in diameter of NSF-listed silicone sealant (Dow Corning RTV-732 or equivalent) around perimeter of dispenser where it meets counter. Smooth sealant to a 1/8" (4mm) radius. 8. Install a PVC drain line with at least a 1/4" per foot (20mm per 1m) slope. Insulate drain line to prevent condensation. Note: Do not apply excessive heat if any sweating of fittings is necessary. Heat conduction through metal may melt threads in plastic drain. Do not reduce drain line size or tie drains together. Note: See instruction enclosed with carbonator pump for detailed installation instructions. 9. Use supplied bolts and lock washers to attach carbonator pump assembly to side of dispenser opposite ice dispense tower. Tighten bolts securely. 10. Connect the 3/8" water line from the dispenser to the 3/8" male flare pump outlet connection. 11. Trace the pump power cord to identify the pump twist lock plug and connect to the female twist lock connector on the dispenser. 12. Make electrical connections in accordance with applicable wiring diagrams provided. Provide disconnects within 10 ft (3m) of dispenser and icemaker for servicing. 7 Field wiring diagrams Note: Field wiring diagrams are intended to aid electricians or technicians in understanding how equipment works. All field wiring must be installed in accordance with all local and NEC codes. If attaching ICEMAKER #1 optional icemaker (OPTIONAL) ELECTRIC accessory LOWER JUNCTION BOX DISPENSER LEFT JUNCTION BOX RIGHT JUNCTION BOX BL Y RD W B LOWER JUNCTION BOX ICEMAKER #2 (OPTIONAL) W B Electric Power Source GND GRN B W ELECTRIC XGND GRN B W UPPER JUNCTION BOX POWER SOURCE LEGEND WIRENUT FIELD CONNECTIONS X EQUIPMENT GROUND B BLACK W WHITE G...