Инструкция по эксплуатации Follett, модель VU300

Производитель: Follett
Размер: 847.56 kb
Название файла: c90a1c8b-1e55-4b7c-a46c-35ae8e238235.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


drains electrical conn. 6" min 17" (432 mm) 18.875" (479mm) 18.875" (479mm) ice transport tube 12" min counter top 32.375" (823mm) Side View 24.62" (626mm) 30" (762mm) 15" (381mm) 10" (254mm) 2" (51mm) ice waterbath (VU300B only) 8.5" (216mm) ice transport tube entry 27.5" (699mm) bin signal power 3/4" drain nipple 1/2" ID drain tube beverage lines 6 Dual-sided dispensers Required clearances 60" (1524mm) above counter for installation if dispenser will be dropped into counter 49" (1245mm) above counter for all units after installation for auger cleaning and servicing 12" (305mm) on dispense chute side of all models for connections 12" (305mm) on side opposite dispense chute if ice transport tube enters side opposite chute 12" (305mm) on side opposite dispense chute on all dual-sided dispensers for connections 43.875 Front View (1115mm) (shown with two Chewblet ® MC400A auto-fill icemaker kits) 25.25" (642mm) counter top Manual load unit Dispenser with 1 optional auto-fill icemaker kit(s) Dispenser with 2 optional auto-fill icemaker kit(s) 6" min 18.875" (479mm) 18.875" (479mm) transport 12" min 12" min. (305mm) 29.625" (753mm) electrical connections beverage lines exit through bottom of chase ice tube 54.875" (1394mm) 17" (432 mm) Ice dispense chute side view Ice dispense chute opposite side view 32.375" (823mm) 16.875" (429mm) 15" 27.5" (699mm) 3/4" FPT drain 3/4" drain nipple ice tube entry beverage lines exit through bottom of chase 27.5" (699mm) 10" (254mm) alt. ice transport tube entry 13.25"13.25" bin signal power (337mm) (337mm) (318mm) (762mm) 30" 7 Installation Installing dispenser in counter Note: All dispensers must be supported from below with supplied 4" – 6" (102 – 153mm) adjustable leg accessory, or equivalent. Do not hang dispenser on flange. All dispensers must be installed level in both directions to ensure proper operation. 1. Check that dispenser location meets all requirements in this manual and cut counter as shown. Plan View Plan View Single-sided dispensers Dual-sided dispensers counter cut-out counter cut-out Shaded area is additional cut-out required for Dual-sided dispensers cannot be slid into counter unless Min. 33" (839mm) flat surface 30.375" (772mm) 38.5" (978mm) 42.5" (1080mm) 11.625" (296mm) 11.625" (296mm) 7.125" (181mm) Min. 33" (839mm) flat surface slide-in installations only 30.375" (772mm) 38.5" (978mm) raised above counter. Call factory for details. 2. Place support blocks in cabinet to raise dispenser to a height of 12" (305mm). 3. Place dispenser in counter onto support blocks. 4. Attach adjustable legs to dispenser. 5. Remove support blocks and lower dispenser feet to floor. 6. Adjust legs for 1/8" (4mm) clearance between dispenser lip and countertop to verify there is no load on flange. 7. Apply a bead approximately 1/4" (6mm) in diameter of NSF-listed silicone sealant (Dow Corning RTV-732 or equivalent) around perimeter of dispenser where it meets counter. Smooth sealant to a 1/8" (4mm) radius. 8. Install a PVC drain line with at least a 1/4" per foot (20mm per 1m) slope. Insulate drain line to prevent condensation. Note: Do not apply excessive heat if any sweating of fittings is necessary. Heat conduction through metal may melt threads in plastic drain. Do not reduce drain line size or tie drains together. 9. Make electrical connections in accordance with applicable wiring diagrams provided. Provide disconnects within 10 ft (3m) of dispenser and icemaker for servicing. 8 Field wiring diagrams Note: Field wiring diagrams are intended to aid electricians or technicians in understanding how equipment works. All field wiring must be installed in accordance with all local and NEC codes. If attaching optional Chewblet MC400A ICEMAKER #1 auto-fill icemaker kit(s) (OPTIONAL) ELECTRIC LEGEND WIRENUT FIELD CONNECTIONS X EQUIPMENT GROUND B W GRN BL Y DISPENSER LEFT JUNCTION BOX RIGHT JUNCTION BOX BL Y RD W B LOWER JUNCTION BOX ICEMAKER #2 (OPTIONAL) W B XGND GRN B W LOWER JUNCTION BOX UPPER JUNCTION BOX BLACK WHITE GREEN BLUE YELLOW RD RED POWER SOURCE XGND GRN B W UPPER JUNCTION BOX ELECTRIC POWER SOURCE Electric Power Source GND GRN B W Connecting beverage lines 1. Connect syrup and water lines. Non-carbonated water line will be labeled “water”. Syrup lines are numbered and correspond to the valves as shown in drawing(s) below. Valve one is always next to ice tower. 2. The center 4 valves are pre-plumbed to both carbonated and non-carbonated water lines with the QuickCARB™ beverage manifold. Valves can be individually changed from a carbonated to a non-carbonated flavor with the flip of a lever (see below). 3. Clean and sanitize beverage lines according to cleaning instructions. Valve position #1 is always next to ice VU300B QuickCARB manifold tower. Left-hand unit shown. (see dispenser for model specific QuickCARB configuration) Rear View carbonated non-carbonated 9 Installing optional auto-fill icemaker kit(s) Correct installation of Satellite-fill icemaker(s) is criti...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории