Инструкция по эксплуатации Turbo Air, модель TBD-4SD

Производитель: Turbo Air
Размер: 203.34 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


-Do not use an abrasive cleaner because it will scratch the surface. 2. CLEANING THE CONDENSER FINS -To maintain proper refrigeration performance, the Condenser coil must be free of dust, dirt, and grease. This will require periodic cleaning. Condenser fins should be cleaned at least every three months (90 days) or as needed. -To clean condenser, unplug the unit. Condenser can be cleaned with vacuum, brush, or CO2 (high pressure air). 3. CLEAN THE GASKET -The door gasket should be cleaned frequently to maintain proper sealing. 4. CLEAN THE DRAIN PAN -Empty the Drain Pan which is located under the unit, periodically. -When reinstalling Drain Pan, make sure Drain Hose is placed back in pan. 5. CHECK AFTER CLEANING -Plug unit back in. -Check that the unit is operating properly. 8 Turbo air BASIC OPERATION REFRIGERATORS 1. The controller(thermostat) is located at the back right inside of the unit. 2. The factory setting maintains about 38°F(3°C) inside. 3. Set toward “counter clock wise” warmer temperature and “clock wise” for colder temperature. Temperature Controller (Thermostat) 4. The thermostat controls compressor’s cycling by sensing inside temperature. 5. When unit will not be used for a long time, unplug the unit. 9 Turbo air BEFORE REQUESTING SERVICE SYMPTOMS CAUSES SOLUTIONS Cooler is freezing products • Thermostat set too cold. • Turn the temperature dial to a warmer setting. The unit does not refrigerate at all. • There is a power connection failure problem. • Check the power cord to make sure the unit is pluged in it correctly. The unit does not refrigerate well. • The unit is in sunlight or near a heating device. • Product was put in warm. • The unit door is opened too frequently or left open too long. • The temp. dial is not on the correct position. • The condenser is clogged. • Move out of sunlight or away from heater. • Check the condition of stored food. • Check the position of the temp control dial. There is a loud noise. • The floor is too weak or the leveling feet are set incorrectly. • The backside of the unit is too close to the wall. • Check the installation. There are dew-drops on the unit exterior. • High-moisture air can produce dewdrops during rainy seasons. • Wipe with a dry cloth. There are dew-drops on the unit interior. • The door is opened too frequently or left open too long. • Keep the door closed to remove dewdrops. The following points are not malfunctions: • A water-flowing sound can be heard when the compressor stops. This is the sound of REFRIGERANT flowing. • The compressor does not run during the defrost cycle. 10 Turbo air Warranty Warranty Claims All claims for labor or parts must be made directly through Turbo Air. If unit was manufactured more than one year, proof of purchase must be faxed in or sent with claim. All claims should include: model number of the unit, the serial number of the cabinet, and all pertinent information supporting the existence of the alleged defect. If compressor is replaced under...

Эта инструкция также подходит к моделям:
Диспенсеры - TBB-1SB (203.34 kb)
Диспенсеры - TBB-1SB (203.34 kb)
Диспенсеры - TBD-1SB (203.34 kb)
Диспенсеры - TBD-1SD (203.34 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории