Войти:
Оценок - 4, средний балл: 4 ( )

Инструкция по эксплуатации Bunn, модель AF PR-2

Производитель: Bunn
Размер: 1014.72 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


• Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are energized for more than ten minutes without a supply of water. • The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help to avoid twists and kinks in the tubing. • Make certain that all plumbing connections are sealed and electrical connections tight and isolated. • Keep away from combustibles. WARNING – • Exercise extreme caution when servicing electrical equipment. • Unplug the dispenser when servicing, except when electrical tests are specified. • Follow recommended service procedures • Replace all protective shields or safety notices 28791.1 011500 4 TROUBLESHOOTING (cont.) PROBLEM Product will not dispense Motor thermal cutout (motor stops running) PROBABLE CAUSE 1. Empty product container 2. No power or incorrect voltage to the dispenser 3. Signal cable unplugged 4. Hopper is full 5. Fuse and fuse holder 6. Main ON/OFF switch 7. Probe box LOW/OFF/HIGH switches 8. Circuit board 9. Vacuum switches 10. Vacuum/Supply pump 1. Motor over heats REMEDY Replace or refill (A1) Check the outlet for 120 volts on two wire 120 volt dispenser. (A2) Check the outlet for 200 volts or 240 volts ac for two wire 200 volt or 240 volt dispensers. (B) Check circuit breakers or fuses. Signal cable must be plugged in. Product must not be touching probes to fill. Refer to Service - Fuse and Fuse Holder for test procedures. See page 8 Refer to Service - Main ON/OFF Switch for testing procedure. See page 9 Refer toService- Probe System. See page 10 Refer to Service- Circuit Board for testing procedures. See page 7 Refer to Service- Vacuum Switches for testing procedures. See page 14 Refer to Service - Vacuum/ Supply Pump for testing procedures. See page 12 The thermal switch will reset, but requires up to 30 minutes of cooling time. See NOTE below. NOTE: This refill unit should not be used to initially fill the hopper. Running the motor for extended periods will trip the thermal switch. The thermal switch will reset, but requires up to 30 minutes of cooling time. 28791.1 011500 6 SERVICE This section provides procedures for testing and replacing various major components used in this dispenser should service become necessary. Refer to Troubleshootingfor assistance in determining the cause of any problem. WARNING -Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. The dispenser should be unplugged when servicing, except when electrical tests are required and the test procedure specifically states to plug-in the dispenser. COMPONENT ACCESS WARNING -Disconnect the dispenser from the power source before the removal of any panel or the replacement of any component. All components are accessible by removing the eight #8-32 screws (five on the front and three on the rear) securing the main housing to the main mounting panel. Refer to Fig. 1 Refer to the contents listing for component location. Contents Circuit Board...........................................................8 Fuse & Fuse Holder ................................................9 Main ON/OFF Switch.............................................10 Probe LOW/OFF/HIGH Switches ...........................11 Refill ON/OFF Switches ........................................ 12 Vacuum/Supply Pump Assembly..........................13 Vacuum/Supply Pump Tubing Installation............14 Vacuum Switches .................................................15 Wiring Diagrams..............................................16,17 1 2 FLAFLAVORORINPUTINPUTMIXED PRMIXED PRODUCT OUTPUT ODUCT OUTPUT 2 1 1 2 3 3 3 WATERTERINPUTINPUTREFILLREFILLMAINMAINPOWERWERFIG. 1 COMPONENT ACCESS P1561 28791.1 011500 7 SERVICE FUSE AND FUSE HOLDER FIG. 4 FUSE HOLDER 1 2 FLAFLAVORORINPUTINPUTMIXED PRMIXED PR ODUCT OUTPUT ODUCT OUTPUT 2 1 1 2 3 3 3 WATERTERINPUTINPUTREFILLREFILLMAINMAINPOPOWERWERP1561 Removal and Replacement: Fuse: 1. Remove the cap from the fuse holder. 2. Remove fuse from the fuse holder, inspect, if blown discard. 3. Install new 10 amp fuse in the fuse holder. 4. Reinstall fuse holder cap. Fuse Holder: 1. Disconnect the wires from the rear of the fuse holder. 2. Remove the nut securing the fuse holder to the front of the main mounting panel. Location: The fuse holder is located on the lower right front of the autofill box just to the left of the power cord. Test Procedure: 1. Disconnect the dispenser from the power source. 2. Remove cap and fuse from fuse holder. 3. Remove fuse from the cap. 4. Check for continuity through the fuse. If continuity is present as described, reinstall the fuse, the fuse is operating properly. If continuity is not present as described, replace the fuse. 3. Push the fuse holder through the hole in the panel. 4. Install new fuse holder and fuse through the hole in the panel. 5. Secure the fuse holder to the panel. 6. Refer to Fig 5 and reconnect the wires...

Эта инструкция также подходит к моделям:
Диспенсеры - AF PR-3 (1014.72 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории