If you get your water from a public water utility, contact the utility to find out if free chlorine or combined chlorine is used in the water system. The CP-07BLO system is designed to remove pentavalent arsenic. It will not convert trivalent arsenic to pentavalent arsenic. The system was tested in a lab. Under those conditions, the system reduced 0.050 mg/L pentavalent arsenic to 0.010 mg/L (ppm) (the USEPA standard for drinking water) or less. The performance of the system may be different at your installation. Have the treated water tested for arsenic to check if the system is working properly. The RO component of the CP-07BLO system must be replaced every 20 months to ensure the system will continue to remove pentavalent arsenic. The component identification and locations where you can purchase the component are listed in the installation/operation manual. * VOC Surrogate Claims * VOC Surrogate Claims Chemical Drinking water regulatory level1 (MCL/MAC) mg/L Influent challenge concentration2 mg/L Chemical reduction percent Maximum product water concentration mg/L alachlor 0.002 0.050 > 98 0.0013 atrazine 0.003 0.100 > 97 0.0033 benzene 0.005 0.081 > 99 0.0013 carbofuran 0.04 0.190 > 99 0.0013 carbon tetrachloride 0.005 0.078 98 0.00184 chlorobenzene 0.1 0.077 > 99 0.0013 chloropicrin -0.015 99 0.00023 2,4-D 0.07 0.110 98 0.00174 dibromochloropropane(DBCP) 0.0002 0.052 > 99 0.000023 o-dichlorobenzene 0.6 0.080 > 99 0.0013 p-dichlorobenzene 0.075 0.040 > 98 0.0013 1,2-dichloroethane 0.005 0.088 955 0.00485 1,1-dichloroethylene 0.007 0.083 > 99 0.0013 cis-1,2-dichloroethylene 0.07 0.170 > 99 0.00053 trans-1,2-dichloroethylene 0.1 0.086 > 99 0.0013 1,2-dichloropropane 0.005 0.080 > 99 0.0013 cis-1,3-dichloropropylene -0.079 > 99 0.0013 dinoseb 0.007 0.170 99 0.00024 endrin 0.002 0.053 99 0.000594 ethylbenzene 0.7 0.088 > 99 0.0013 ethylene dilbromide (EDB) 0.00005 0.044 > 99 0.000023 haloacetonitriles (HAN) bromochloroacetonitrile dibromoacetonitrile dichloroacetonitrile trichloroacetoritrile ---- 0.022 0.024 0.0096 0.015 98 98 98 98 0.00053 0.00063 0.00023 0.00033 haloketones (HK): 1,1-dichloro-2-propanone 1,1,1-trichloro-2-propanone -- 0.0072 0.0082 99 96 0.00013 0.00033 heptachlor (H-34,Heptox) 0.0004 0.08 > 99 0.0004 heptachlor epoxide 0.0002 0.01076 98 0.00026 hexachlorobutadiene -0.044 > 98 0.0013 hexachlorocyclopentadiene 0.05 0.060 > 99 0.0000023 lindane 0.0002 0.055 > 99 0.000013 methoxychlor 0.04 0.050 > 99 0.00013 pentachlorophenol 0.001 0.096 > 99 0.0013 simazine 0.004 0.120 > 97 0.0043 styrene 0.1 0.150 > 99 0.00053 1,1,2,2-tetrachloroethane -0.081 > 99 0.0013 tetrachloroethylene 0.005 0.081 > 99 0.0013 toluene 1 0.078 > 99 0.0013 2,4,5-TP (silvex) 0.05 0.270 99 0.00164 tribromoacetic acid -0.042 > 98 0.0013 1,2,4-trichlorobenzene 0.07 0.160 > 99 0.00053 1,1,1-trichloroethane 0.2 0.084 95 0.00464 1,1,2-trichloroethane 0.005 0.150 > 99 0.00053 trichloroethylene 0.005 0.180 > 99 0.00103 trihalomethanes (includes): chloroform (surrogate chemical) bromoform bromodichloromethane chlorodibromomethane 0.080 0.300 95 0.015 xylenes (total) 10 0.070 > 99 0.0013 1. These harmonized values were agreed upon by representatives of USEPA and Health Canada for the purpose of evaluating products to the requirements of this Standard. 2. Influent challenge levels are average influent concentrations determined in surrogate qualification testing. 3. Maximum product water level was not observed but was set at the detection limit of the analysis. 4. Maximum product water level is set at a value determined in surrogate qualification testing. 5. Chemical reduction percent and maximum product water level calculated at chloroform 95% breakthrough point as determined in surrogate qualification testing. 6. The surrogate test results for heptachlor epoxide demonstrated a 98% reduction. These data were used to calculate an upper occurrence concentration which would produce a maximum product water level at the MCL. Woongjin Coway.,Ltd. 658, Yugu-Ri, Yugu Eub, Gongju-Si, Choongchungnam-Do, Korea Tel.: 82-41-850-7879 Fax.: 82-41-841-7816 Manufacturer:WoongjinCowayCoLTDThewatertreatmentdevice(s)listedonthiscertificatehavemetthetestingrequirementspursuanttoSection116830oftheHealthandSafetyCodeforthefollowinghealthrelatedcontaminants: Microbiological Contaminants and Turbidity Inorganic/Radiological Contaminants None Arsenic1BariumCadmiumChromium(hexavalent) Chromium(trivalent) LeadNitrate/Nitrite2Radium226/228SeleniumOrganic Contaminants VOCs Alachlor Endrin SimazineAtrazine Ethylbenzene StyreneBenzene EDB 1,1,2,2-TetrachloroethaneCarbofuran Haloacetonitriles(HAN) TetrachloroethyleneCarbonTetrachloride Bromochloroacetonitrile TolueneChlorobenzene Dibromoacetonitrile 2,4,5-TP(Silvex) Chloropicrin Dichloroacetonitrile TribromoaceticAcid2,4-D Trichloroacetonitrile 1,2,4-TrichlorobenzeneDBCP Haloketones(HK) 1,1,1-Trichloroethaneo-Dichlorobenzene 1,1-Dichloro-2-Propanone 1,1,2-Trichloroethanep-Dichlorobenzene 1,1,1-Trichloro-2-Propanone...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории