|
Фото и характеристики Sony ICD-B200 |
К этому устройству также есть другие инструкции:
Фрагмент инструкции
Message 3 Display window Folder indication Alarm indicator Repeat play indicator Selected message number REC DATE (recorded date) indication REMAIN indicator Message 1 Message 2 Message 3 Message 4 Message 5 Message 1 Message 2 Message 3 Message 4 Message 1 Message 2 Message 3 Blank space Message 1 Message 2 Folder B e.g. Folder A Blank space Message 1 Message 2 Message 3 1Press FOLDER to select the folder you want to erase. 2While pressing xSTOP, press ERASE for more than 1 second. “ALL ERASE” will flash for 10 seconds. Message 3 A message is divided. Recording continues Message 1 Message 2 HOLD During playback of Message 3 After adding a recording Message 4 at Conference room A Message 4 Added recording Message 3 Message 3 Meeting at 2 o’clock on December 1. Recording with an External Microphone or from Other Equipment 1 Connect a plug-in-power type microphone or other equipment to the MIC (PLUG IN POWER) jack. When recording with an external microphone When you connect an external microphone, the built-in microphone is automatically cut off. When a plug in power type microphone is connected, power is automatically supplied to the microphone from the IC recorder. When recording from other equipment 2 Follow the steps in “Recording messages” to record messages. Notes • Make sure that the plugs are connected securely. • We recommend you make a trial recording to check the connections and volume control. • When connecting equipment other than Sony’s, refer to the instruction manual of the equipment. MIC mini-plug (monaural) External microphone (not supplied) Message 4 The message numbers increase. A message is divided. Message 1 Message 2 Message 3 Message 1 Message 2 Message 3 MIC jack (PLUG IN POWER) EAR (earphone) jack OPR (operation) indicator ERASE FOLDER VOL (volume) +/– DIVIDE HOLD xSTOP Remaining memory indicator Remaining battery indicator Recording mode indication REC (recording) indicator Number of messages in a folder/Menu indication/Counter /Remaining time indication / Recording date indication /Current time indication / Messages MIC Tape recorder, TV, radio, etc. Audio connecting cable with attenuator (not supplied) EAR,EARPHONE, v or REC OUT mini-plug (monaural) mini-plug (stereo or monaural) Starting recording automatically in response to the sound — Advanced VOR function VOR ON: The VOR (Voice Operated Recording) function is activated. Recording starts when the unit detects sound and stops when no sound is heard, eliminating recording from soundless period. VOR OFF: The VOR function is disabled. Normal recording operation is selected. 1 Press MENU to enter the menu mode. 2 Press – . or >+ to display “VOR” and press NxPLAY/ STOP. “OFF (or ON)” will flash. 3 Press – . or >+ to select “ON” or “OFF” and press NxPLAY/STOP. Now the setting is completed. 4 Press MENU to exit the menu mode. Selecting the Display Mode You can select the display mode for the stop, recording and playback modes. Each time you press DISPLAY, the display mode will change as shown below: 1 On the current time display If the unit is left unoperated for more than 3 seconds in the stop mode, the display will show the current time, regardless of the display mode setting. Counter: Elapsed playback/recording time in one message m Remaining recording time (REMAIN): In the playback mode: The remaining time of one message indication. In the stop and recording mode: The remaining recording time indication. m Recorded date (REC DATE)*: The date the current message was recorded. m Recorded time (REC DATE)**: The time the current message was recorded. * If the clock has not been set, “--Y--M--D” will be displayed. **If the clock has not been set, “--:--” will be displayed. Specifications Recording media Built-in flash memory 16MB (ICD-B100)/32MB (ICD-B200), Monaural recording Recording time ICD-B100: HQ: 1 hour 45 minutes SP: 4 hours 50 minutes LP: 8 hours ICD-B200: HQ: 3 hours 40 minutes SP: 9 hours 50 minutes LP: 16 hours 10 minutes Frequency range HQ: 250 Hz - 6,800 Hz SP/LP: 220 Hz - 3,400 Hz Speaker approx. 2.0 cm (13/16 in.) dia. Power output 250 mW Input/Output •Earphone jack (minijack) for 8 - 300 ohms ear receiver/headphones •Microphone jack (minijack, monaural) Plug in power Minimum input level 0.6 mV 3 kilohms or lower impedance microphone Power requirements Two LR03 (size AAA) alkaline batteries: 3 V DC Dimensions (w/h/d) (not incl. projecting parts and controls) 30.0 . 103.5 . 16.0 mm (1 3/16 . 4 1/8 . 21/32 in.) Mass (incl. batteries) 58 g (2.1 oz) Supplied accessories Operating instructions (1) LR03 (size AAA) alkaline batteries (2) (For the U.S.A. and U.K. only) Optional accessories Electret Condenser Microphone ECM-C10, ECM-DM5P, ECM-Z60, ECM-TL1 (for telephone recording) Audio connecting cable RK-G64HG /RKG69HG (excluding Europe) Active speaker SRS-T88, SRS-T80 Your dealer may not handle some of the above listed optional accessories. Please ask the dealer for detailed information. Design and specifications are subject...
Эта инструкция также подходит к моделям:Диктофоны - ICD-B100 (825.89 kb)