|
Фрагмент инструкции
Introduction However please note when there are 5 free mem- You are about to enjoy an advanced Cumula ories left, the icon “FULL” will blink to remind you of the nearly full situation. Whenever the storage tive and Lap memory professional digital quartz stopwatch with advanced timing features. Models is full, extra split/lap times will NOT be stored into AX602M500 & AX602M500DEC Stopwatches memory even though you reset your stopwatch and start a new event. Extra split/lap times will include Time of day, Daily Alarm, Chronograph stopwatch, 500 memory, Data register, Count- only be shown on the display but not recorded. down timer, Stroke Measurement timer, and Pacer In order for the stopwatch to record the lap/split (from 5 to 240 beats per minute). times again, you must delete the data in the DATA Model AX602M500DEC Decimal Stopwatch memory. Please refer to the “Data Mode” section in the instruction manual for how to delete the includes Decimal timing (1/100 of a sec, memory. 1/1000 of a minute, 1/100,000 of an hour). Model AX602M500 Speed Stopwatch includes Speed Measurement. 2 3 4-5 General Features . Three operating modes (Countdown Repeat, Countdown Stop, Countdown then count up) . ACCUSPLIT X case with ergonomic design and for countdown timer no-fail buttons . Stroke/Stride measurement basing on “3” . 4 button operation . Speed measurement (AX602M500 Model only) . Large LCD display with contrast adjustment . Decimal second, minute and hour chronograph . 12/24 hour display (AX602M500DEC Model only) . Time of day and chime . Beep sound selectable . Daily alarm . Uses long life Lithium CR2032 battery for years . Full 1/100 second chronograph with working of use between battery changes range from 0 to 19 hr. 59 min. 59.99 seconds . Low battery check with 500 memory records of split and lap time. The operation of the stopwatch is divided into . Recall function for recorded split and lap times nine modes. As you choose each “mode”, a . Count-Down timer with working range from 0 to message will be displayed for a second before 19 hr. 59 min. 59.9 seconds you enter the mode: 4 5 6-7 6 7 Button Operation • MODE - used to change the watch’s operating mode • START • SPLIT - used to start the timer or stopwatch, and for taking split and lap times • RECALL - used to recall recorded split and lap times (memories) • STOP • RESET - used to stop and reset the stopwatch or timer TIME Speed mode (AX602M500 only) Normal Time mode Alarm mode SPEED ALARM Chronograph mode CHRONO LapTime Recall mode RECALL Data mode DATA Timer mode TIMER Pacer mode PACER Stroke Measurement STROKE RECALL SPLIT or STOP Press MODE to cycle through: 8-9 8 9 This is only a brief description of these buttons. Detailed uses of the buttons are different in particular functions and will be described later in the instructions. Pressing [MODE] button will toggle among the modes above. Note that there is no auto-return function in the stopwatch. Whenever you change modes, the stopwatch will remain in that mode until the [MODE] button is pressed again. Time of Day Mode The starting point for operating your stopwatch is TIME OF DAY. If TIME OF DAY is not displayed, press [Mode] until it is. Year : - 2008 Date : - January 1 Day of week : - Monday Time : - 12:00 am The display format is as below : ° year ° day, month - date ° hr : min second 10-11 ACCUSPLIT products use a common setting procedure known as S1-S2-S3-S4. S1 (2 sec) - Enter set function OR S1 (4 sec) - Enter set function & clear the current settings S2 – Select field to be set (selected field will flash) S3 – Set field to desired settings S4 – Exit setting function During clock display, press [START • SPLIT] to switch between 12 hr and 24 hr display mode. To toggle chime ON or OFF, you can press [STOP • RESET]. The bell icon will be ON or OFF correspondingly. Normal Time Setting Press and hold [RECALL] (S1) for 2 seconds to MODEHour S3S1/S4S2 enter setting mode. The normal time setting starts with second. The second digits will be fl ashing. Year You can change the flashing digit by pressing Month and date [START • SPLIT] (S3) button. To speed up the setting you can press and hold [START • SPLIT] Seconds for longer than 2 seconds to activate fast setting. To select other digits, press [STOP • RESET] Minutes (S2) button. The setting order is: Second, Minute, Hour, Year, Month, Date, month-date (m-d) or 10 11 12-13 date-month (d-m), Sound ON or OFF, Contrast Press [START • SPLIT] conse( darkness of the digits - default is 9), then back to cutively to advance the contrast Second, and recycles again. up to 16, then cycle back to 1. C O n T 1 6 The contrast setting will be Note: when the second is to be set, press [START shown on the display. • SPLIT] to reset the second digits to zero. At the end of setting, press [RECALL] (S4) or [MODE] to NOTE: exit from the setting mode and back to Time of • The hour digits may be displayed in 12 hr or Day Display. S O U n d O n S O U n d O n 24 hr format. Displa...
Эта инструкция также подходит к моделям:Часы - AX602M500DEC (1.25 mb)