|
Фрагмент инструкции
Special caution is suggested for younger children. Pregnant women beware! Soaking in water above 102°F can cause fetal damage during the first three months of pregnancy (resulting in the birth of a brain-damaged or deformed child). Pregnant women should adhere to the 100°F maximum rule. Before entering the spa or hot tub, users should check the water temperature with an accurate thermometer; operating ther mostats may err in regulating water temperatures by as much as four degrees Fahrenheit. Persons with a medical history of heart disease, circulatory problems, diabetes, or blood pressure problems should obtain their physician’s advice before using spas or hot tubs. Persons taking medications which induce drowsiness, such as tranquilizers, antihistamines, or anticoagulants, should not use spas or hot tubs. If the pool/spa is used for therapy, it should be done with the advice of a physician. Always stir the water before entering to mix in any hot surface water that might exceed healthful temperature limits and cause injury. Do not tamper with controls, because scalding can result if safety controls are not in proper order. Temperature controls: The heater is turned “ON” and “OFF” and the water tempera ture is adjusted with the thermostat. Turning the thermostat all the way counterclockwise will turn the heater “OFF.” Turning the thermostat clockwise will turn the heater “ON” and adjust the tempera ture higher. The memory stop provides a manual means of locking the desired maximum temperature setting of the water. Once the maximum setting has been determined, loosen the screw and rotate the stop to the desired location and retighten the screw . Periodic inspection: 1. Periodically check the venting system on the heater . The venting areas must never be obstructed in any way and minimum clearances must be observed to prevent restriction of combustion and ventilation air. 2. Keep the entire pool area clean and free of all debris, com bustible materials, gasoline and other flammable vapors and liq uids. Remove any leaves or paper from around the heater . 3. Do not store chlorine, other pool chemicals or other corro sives in the vicinity of the heater. Winterization: Do not operate heater if the temperature falls below 40°F. Drain all water out of heater to prevent damage to heatexchanger during freezing weather. Section IV. Qualified Technician - Servicing General: WARNING: Do not attempt to repair any components of heater. Do not modify heater in any manner . To do so may result in a malfunction which could result in death, personal injury , or property damage. Check with consumer to see if any part of heater has been under water. Replace any part of the control sys tem and any gas control which has been under water . Never use or attempt to use parts that have been previously used. CAUTION: Label all wires prior to disconnection when servic ing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Burner cleaning: If required, burners can be cleaned in the following manner: 1. Turn pump, main gas valve and heater power of f. 2. Remove the gas manifold. 3. Remove the burners. 4. Brush burners with a wire brush and check that they are free of lint. dust and spider webs before each season of use. Burners with damaged ports must be replaced. Gas valve replacement: WARNING: Do not attempt to repair gas valve. If found defective, replace entire valve. Attempts to repair it will void warranty. 1. Turn pump, main gas valve and heater power of f. 2. Disconnect wires to gas valve. 3. Unscrew gas valve from manifold. 4. Install new valve. 5. Reconnect wires to gas valve. Direct spark module: The direct spark ignition module is the master control, process ing the operational information from the other controls. When thethermostat calls for heat, the blower turns on for 10 seconds before the ignitor begins to spark The ignitor begins sparking atthe same time the main gas valve opens, which causes ignition ofthe main burner gas. If ignition does not happen within 10 sec onds, the module will try to light for (3) consecutive tries at 30 sec ond intervals. If no ignition is received the control will lock out for 1hour. To reset the module, the thermostat must be turned to the “OFF” position and back “ON”. To replace the module: 1. Turn pump, main gas valve and heater power of f. 2. Unplug heater. 3. Disconnect wires from the module. 4. Remove module retaining screws. 5. Replace module. Combustion blower: The combustion blower provides the air that mixes with thegas from the main burners for the combustion process. On initialstart-up, the blower operates for 10 seconds to purge gas out ofthe heater. Then, the main gas valve opens, the ignitor sparks fora maximum of 10 seconds and the heater lights. The blower operates the entire time the gas valve is open. Combustion blower replacement: 1. Turn pump, main gas valve, thermostat and heater power “OFF”. 2. Remove screws ret...
Эта инструкция также подходит к моделям:Бассейны - ABG1001 (502.06 kb)