|
Инструкция по эксплуатации STA-RITE, модель Swimming Pool Filter
Производитель: STA-RITE Размер: 446.92 kb Название файла: PLM_sys_OM.pdf
Язык инструкции:
|
|
|
|
Перейти к скачиванию
Фрагмент инструкции
Sta-Rite Pool/Spa Group U.S. PATENT NO. 5190651 (Other patents pending) This manual should be furnished to the end user of this filter; its use will reduce service calls and chance of in- jury and will lengthen filter life. 2160 1295 OUTLETOUTLET RELEASERELEASE 2160 1295 OUTLETOUTLET RELEASERELEASE 293 Wright Street, Delavan, WI 53115 North America: 800-752-0183, FAX 800-582-2217 International: 262-728-5551, FAX: 262-728-4461, TELEX: ITT 4970245 Union City, TN • Delavan, WI • Mississauga, Ont. • Murrieta, CA © 2000, Sta-Rite Industries, Inc. Printed in U.S.A. S340 (Rev. 1/25/00) SYSTEM 3™ MODULAR MEDIA FILTER SYSTEM To avoid unneeded service calls, prevent possible injuries, and get the most out of your filter system, READ THIS MANUAL CAREFULLY! The System 3™ Modular Media Filter System Pool Pumps: • Without a cord or with a 3’ cord or no cord are for use with permanently installed pools ONLY (see CAUTION #7, below). • With a 25’ cord are for use with storable pools ONLY (see CAUTION #8, below). Table of Contents Safety Instructions ......................................................................................2-3 General Information ......................................................................................4 Specifications / Model Numbers and Descriptions.........................................5 Installation ....................................................................................................6 Electrical .......................................................................................................7 Initial Startup / Operation ..............................................................................8 Filter Disassembly / Assembly ..................................................................9-10 Module Cleaning Procedure........................................................................10 Special Cleaning Instruction.....................................................................10 System Inspection / Winterizing...................................................................11 Pump Service .........................................................................................11-12 Troubleshooting Guide - Pump....................................................................13 Troubleshooting Guide - Filter .....................................................................14 Repair Parts List......................................................................................15-18 Warranty .....................................................................................................19 IMPORTANT SAFETY INSTRUCTIONS When installing and using electrical equipment, basic safety precautions should always be followed, including the following: 1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 7. Permanent pool pumps are for use with per 2. To reduce the risk of injury, do not permit manently installed pools and may also be used with hot children to use this product unless they are closely super- tubs and spas if so marked. Do not use with storable pools. vised at all times. A permanently installed pool is constructed in or on the ground or in a building such that it cannot be readily dis- Risk of electrical shock. Connect only to a assembled for storage. A storable pool is constructed so that grounding type receptacle protected by a ground-fault cir it may be readily disassembled for storage and reassembled cuit-interrupter (GFCI). Contact a qualified electrician if you to its original integrity. cannot verify that the receptacle is protected by a GFCI. 8. Storable pool pumps are for use with 4. Do not bury cord. Locate cord to minimize abuse from storable pools only. Do not use with permanently installed lawn mowers, hedge trimmers, and other equipment. pools. A storable pool is constructed so that it is capable To reduce the risk of electrical shock, of being readily disassembled for storage and reassembled 3. 5. replace a damaged cord immediately. to its original integrity. A permanently installed pool is To reduce the risk of electrical shock, do constructed in or on the ground, or in a building, such that it cannot be readily disassembled for storage. 6. not use an extension cord to connect unit to electrical supply; provide a properly located outlet. SAVE THESE INSTRUCTIONS 2 WARNING Hazardous Pressure! Can cause tank explosion. Do not connect filter to compressed air under any circumstances. READ AND FOLLOW SAFETY INSTRUCTIONS! This is the safety alert symbol. When you see this symbol on your filter or in this manual, look for one of the following signal words and be alert to the potential for personal injury. warns about hazards that will cause death, serious personal injury, or major property damage if ignored. warns about hazards that can cause death, serious personal injury, or major property damage if ignored. warns about hazards that will or can cause minor personal injury or property damage if ignored. NOTICE indicates special ...
Напишите ваш отзыв об устройстве
|
|