|
К этому устройству также есть другие инструкции:
Фрагмент инструкции
* ISF (infrasonic filter) switch When this switch is "ON", the frequencies which are below the audible range and therefore inaudible are cut off so that the quality of the audible frequencies can be improved. ( OPERATION switch This switch is used to select the operation mode of the amplifier. • STEREO position: The amplifier can be used as a stereo amplifier. • MONO (Lch) position: Amplifies the signal input from the left side only. Set to this position and make bridged connections to use as a high-power monaural amplifier. (The input right signal is not output.) ) INPUT SENSITIVITY control Set this control according to the pre-output level of the center unit connected with this unit. NOTE For the pre-output level, refer to the "Specifications" in the instruction manual of the center unit. ................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................ Amplifier Control System Indicator MENU 2 / 3 Display mode You can set up the display items as follows: 1 Enter Menu mode Press the [MENU] button. "VOLT"/"CURR"/"TEMP"/"FAN" is displayed. 2 Select a display item Press the [2] or [3] button. The display items are switched in the following sequence. Display Information "VOLT" Indicates the source voltage (V). "CURR" Indicates the current consumption (A). "TEMP" Indicates the internal temperature (°F/°C). "FAN" Indicates the rotation speed of the cooling fan in 3 steps: "FAST", "SLOW" or "OFF". 3 Exit Menu mode Press the [MENU] button for at least 1 second. NOTE When the internal temperature is -22°F/-30°C or less, "-22F"/"-30C" is displayed. Separate Amp Control You can control sounds using the Amplifier Control function of the unit. 1 Enter Menu mode Press the [MENU] button. 2 Select the Menu item Press the [MENU] button. The setup items are displayed approximately 1 second first, then the set values are displayed. 3 Adjust the Menu item Press the [2] or [3] button. The setup items and set values are switched as follows. Display Range Adjustment Item "VOLT"/"CURR"/"TEMP"/"FAN" For the operation method refer to 'Display mode' "BASS" 60/80/100/200 (Hz) Bass Center Frequency "BA G" B–15 — B+15 (dB) Bass level "BA Q" Q1.00/Q1.25/Q1.50/Q2.00 Bass Q Factor " EXT" ON/OFF When the bass extend is set to ON, low frequency response is extended by 20%. "TREB" 10/12/15/17 (kHz) Treble Center Frequency "TR G" T–15 — T+15 (dB) Treble level "VOL" –20 — 0 (dB) Volume offset "TEMP" FAHR (Fahrenheit) or CELS (Centigrade) The Fahrenheit or Centigrade temperature unit can be selected for the Display mode. "DEFA" For the operation method refer to 'Default' "AMP" 0 — 7 The ID Number you have assigned is displayed. 4 Exit Menu mode Press the [MENU] button for at least 1 second. NOTE When you hold down the [3] button 3 or more seconds during ID number display ("AMP"), message "MEMO" is displayed and you can register the values you have set with the Amplifier Control. To call the Amplifier Control’s values, hold down the [2] button 3 or more seconds during ID number display ("AMP"). Then, you can recall the value when message "LOAD" is displayed. Default Resets all values you have set to the initial (default) values. 1 Enter Menu mode Press the [MENU] button. 2 Select Default mode Press the [MENU] button. Select the "DEFA" display. 3 Resets the value to its default Press the [3] button for at least 2 seconds. Message "----" is displayed, and the value is initialized. 4 Exit Menu mode Press the [MENU] button for at least 1 second. NOTE Volume offset value can not be initialized. Display Demonstration The "VOLT"/"CURR"/"TEMP"/"FAN" items are displayed repeatedly. Press the [MENU] button for at least 2 seconds. The indicator flashes in the Demonstration mode. Canceling the Demonstration mode Press any button to cancel the Demonstration mode. Control an Amp from Center Unit You can control the sound by controlling amplifiers from the Center Unit. 1 Enter AMP Control mode Select the AMP Control mode by following the 'AMP Control' procedure given on the Operation Manual of the Center Unit. NOTE Use the set item and value operation buttons by following the instructions given on the Operation Manual of the Center Unit. 2 Select an amp number to operate Operate the desired set item with the Center Unit. Select the "AMP NO"/"AMP CONTROL NO" display. NOTE When the Center Unit is in the STANDBY mode, message "AMP OFF" is displayed and you cannot operate the set items. 3 Set an ID number of Amp to operate Set an amp’s ID number on the Center Un...
Эта инструкция также подходит к моделям:Автоусилители - KAC-PS521 (630.93 kb)
Автоусилители - KAC-X521 (630.93 kb)
Автоусилители - KAC-X621 (630.93 kb)