Войти:
Оценок - 5, средний балл: 3.4 ( )

Инструкция по эксплуатации Crown, модель XTI2 SERIES XTI 6002

Производитель: Crown
Размер: 6.44 mb
Название файла:
Язык инструкции:enesfrde
Перейти к скачиванию



Фрагмент инструкции


output channels. This provides a 6 dB level boost. .. .......................................................................................................................................................................................................................................... signal is ignored. Output Mode .. .............................................................................................................................................................................................................................................. to the Channel 2 output. .. ........................................................................................................................................................................................................................ Subharmonic Synth The Subharmonic Synth feature takes the low frequencies and “synthesizes” or creates new frequencies that are one octave lower. The two signals are then summed together. Also new, are two user adjustable parametric EQ filters and crossover frequency filter. These can be used to “shape” the sound and enhance the desired effect. Equalization The XTi2 Series provides two blocks of equalization in the signal processing. The input EQ block is before the crossover and is usually used for the room EQ. The output EQ block is after the crossover and is usually used for speaking tuning. Input EQ: This input EQ block provides 6 filters per channel each with frequency, gain, and Q that is user controllable. This block also has a High and Low Shelf Filter per channel which has gain and frequency control. Output EQ: This output EQ block provides 8 filters per channel each with frequency, gain, and Q control that is user controllable. Crossover: The crossover section provides users with the ability to enable a HighPass and LowPass filter per channel along with BandPass gain and the ability to change the polarity. This allows the Crossover section to be customized to most system configurations. For the HighPass and LowPass Filters, you have the choice of the following filters: Butterworth 6dB/oct, Butterworth 12dB/oct, Butterworth 18dB/oct, Butterworth 24dB/oct, Butterworth 48dB/oct, Linkwitz-Riley 24dB/oct, and Linkwitz-Riley 48dB/oct. The BandPass gain provides you with -15dB to +15dB of gain. Delay There is up to 50msec of delay available in the signal processing for time aligning your speakers. The software allows you to enter the amount of delay needed in the form of seconds, feet, or meters and does the calculation for you. PeakX Plus Limiter: Feed-forward output limiter with user-adjustable attack, release and threshold (0.1 dB resolution), plus integrated feedback limiter to minimize amplifier clipping. Operation Manual page 11 XTi2 Series Power Amplifiers Integrated Processing Features Advanced Thermal Control In this section, you can tailor the fan speed to specific applications. You have the choice of the following modes: .. ..........M .. ........Z .. ..................E The fan mode can be changed using the front panel buttons at start-up or in the software. The default mode is normal and should work fine for most applications. Early mode turns the fan on sooner at a “lower” temperature, and Full-speed mode turns the fan on full-speed full-time. Full-speed mode is not recommended for “dirty” environments. Advanced Monitoring This feature allows you to have software visibility of both the Power Supply Temperature and AC Line voltage. AC Line voltage is “derived” from the amplifier rail voltage and is an approximation of the AC line voltage. This allows you to monitor the health of your amplifiers and provides for troubleshooting. Front Panel Lock-Out To disable or lock the buttons from the front panel, hold the Prev and Next at the same time until the screen says “locked”. The rotary knobs (attenuators) will still operate. To unlock, hold Prev and Next until the screen says “unlocked”. The front panel can also be locked out from the software as well from the main panel. However once it is locked in the software, it can only be unlocked from the software. You cannot unlock from the front panel. The rotary knobs (attenuators) will still operate. page 12 Operation Manual Weitere Sprachversionen: Um Informationen uber die Nutzung dieses Produktes in anderen Sprachen zu erhalten, wenden Sie sich bitte an Ihren ortlichen Crown- Handler. Wenn Sie Hilfe dabei benotigen, Ihren ortlichen Handler ausfindig zu machen, kontaktieren Sie Crown bitte unter 574-294-8000. Dieses Handbuch enthalt nicht alle Einzelheiten zu Design, Herstellung oder Varianten des Gerates. Es deckt auch nicht jeden moglichen Fall ab, der wahrend Installation, Betrieb oder Wartung auftreten konnte. Die in diesem Handbuch enthaltenen Informationen waren bei Erscheinungsdatum zutreffend. Es konnen jedoch Aktualisierungen zu diesen Informationen vorliegen. Um die neueste Version dieses Handbuchs zu erhalten, besuchen Sie bitte die Crown-Webseit...

Эта инструкция также подходит к моделям:
Автоусилители - XTI2 SERIES XTI 1002 (6.44 mb)
Автоусилители - XTI2 SERIES XTI 2002 (6.44 mb)
Автоусилители - XTI2 SERIES XTI 4002 (6.44 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории