Войти:
Оценок - 6, средний балл: 4.2 ( )

Инструкция по эксплуатации DKS Enterprises, модель 9310

Производитель: DKS Enterprises
Размер: 561.47 kb
Название файла: 9984cf22-4293-4ebc-afd9-85bf4b7b8959.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


All rights reserved. DoorKing, Inc. 120 Glasgow AvenueInglewood, California 90301 U.S.A. Phone: 310-645-0023Fax: 310-641-1586 Use this manual with the following models only. All 9310 models with circuit board 4403-010. IMPORTANT! The 4403 circuit board used in the model 9310 IS NOT interchangeable with the 4402 circuit board used in the earlier model 9300 operators. NOTE: Models 9310-081, 9310-083, 9310-085, 9310-087, 9310-089, 9310-091, 9310-093, 9310- 095 and 9310-097 will have a supplemental manual (P/N 2340-065) that describes the operation and setup of the optional battery backup system available with this unit, and provides additional wiring information for this unit. DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc. Mount operator to pad using 3/8 or 1/2 sleeve anchors. See page 18-19.12Attach chain. Adjust chain to allow approximately 1-inch of sag per 10-feet of gate width. Be sure to remove the pin from the breather plug. See page 20-21.3Connect supply voltage as described in section 2.1. Be sure power is OFF! See page 26.4Connect control wiring as shown. Radio receiver connects to terminals 1-2-3. Full openinput devices connect to terminals 4 and 13. Partial open input devices connect toterminals 5 and 13. Terminals 1 and 13 are the same - 24 volt common. 5Connect secondary entrapment prevention devices. See page 27.6Connect in-ground loop wires to REVERSE and EXIT loop detectors as required. See page 28.7Set close timer ON or OFF (SW-1, switch 2) as required. If gate system does not utilize in- ground loop system or photo-cells, timer must be OFF. See page 34-35.8Push gate to open position. Adjust OPEN limit nut to activate open limit switch. Push gateclosed. Adjust CLOSE limit nut to activate close limit switch. See page 36.9Turn power ON. Give gate an open command. If gate runs towards CLOSE position, turnpower off. Change setting of direction switch (SW-1, switch 1) and then turn power ON. Give gate an open command. Adjust limit nuts as necessary. See page 36.10Adjust both open and close inherent reverse sensitivity. NOTE: Operator will assume a"soft shutdown" during sensitivity adjustments. This will require operator open input to beactivated to resume normal operation. See page 37. QUICK START 94109410EXIT LOOPREVERSE LOOPON1231 DIRECTION2 TIMER1 Open Cycle Photocell2 Close Cycle Photocell3 Open Cycle Contact Sensor4 Close Cycle Contact Sensor5 Common6 CommonSecondaryEntrapmentProtectionDevicesCAUTION16- 20 HIGH VOLTAGE! TIMERREV SENSOPENREV SENSCLOSETIME DELAY1 2 3 4 5 6 7 81 2 3 4ONREVERSELOOPGATE FORCEDEARTH GROUNDCAPACITOR CONNECTORREVERSING DEVICECONNECTOR1234567891011121314151617181920POWEREXITLOOPLIMIT SWITCHCONNECTORLIMITPARTIALLIMITRELAY CONTACTCLOSEOPENSENSITIVITY24V ComRelayRadio Pwr3-WireReceiver4-WireReceiver24V Com -- RelayRelayRadio Pwr + 1123FireDeptNOTETerminal 1 and 13are the same. Either can be usedas a low voltagecommon. Current Sensor DonutHPVolt-PhTurns1/21111AllSgl Ph208-3230-3460-3215 * 5 * 9 * * CURRENT SENSOR DONUTFor 1HP 3-Phase motors, the RED currentsensor wire is connected directly to thelug opposite of terminal 19. The blackmotor wire is routed through the donutwith the number of turns shown in thetable. Refer to the wire diagrams in theback of the manual. Glossary GATE: A moving barrier such as a swinging, sliding, raising, lowering, or the like, barrier, that is a stand-alone passage barrier or is that portion of a wall or fence system that controls entrance and/or egress by persons or vehicles and completes the perimeter of a defined area. RESIDENTIAL VEHICULAR GATE OPERATOR – CLASS I: A vehicular gate operator (or system) intended for use in a home of one-to four single family dwelling, or garage or parking area associated therewith. COMMERCIAL / GENERAL ACCESS VEHICULAR GATE OPERATOR - CLASS II: A vehicular gate operator (or system) intended for use in a commercial location or building such as a multi-family housing unit (five or more single family units), hotels, garages, retail store, or other building servicing the general public. INDUSTRIAL / LIMITED ACCESS VEHICULAR GATE OPERATOR - CLASS III: A vehicular gate operator (or system) intended for use in an industrial location or building such as a factory or loading dock area or other locations not intended to service the general public. RESTRICTED ACCESS VEHICULAR GATE OPERATOR - CLASS IV: A vehicular gate operator (or system) intended for use in a guarded industrial location or building such as an airport security area or other restricted acces...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории