NOTE: DC convenience open systems are optional and your gate system may or may not be equipped with one. Check with your installer to determine if your gate system is equipped with a convenience open system. 3. In the event of a primary (AC) power failure and a back-up system (DC) power failure (low charged or dead batteries for example), the system must have a release system to allow the gate to be manually operated. 6500-065-K-7-08 27 • Be sure that power is removed or shut-off prior to placing the gate operator in manual operation. Manual Release Remove release tool and place where shown. Release hub. Gate can now be manually operated. B C Unlock the cover and rotate sliding door. A CAUTIONDO NOT REMOVE HUB! 286500-065-K-7-08286500-065-K-7-08 SECTION 5 - OPTIONAL CONVENIENCE OPEN ADJUSTMENTS SECTION 5 - OPTIONAL CONVENIENCE OPEN ADJUSTMENTS The optional convenience open system installed in your vehicular gate operator is designed as a convenience enhancement only. It is not designed or intended to provide continuous gate operation during a power outage. Its sole purpose is to provide a method to open the vehicular gate to allow unimpeded traffic flow when the gate and access control system is without power. If your access control system requires 100% power backup and continuous operation when primary (AC) power has failed, a power inverter / backup system, such as DoorKing’s Model 2000, is required. • The convenience open system cannot provide continuous gate operation during a power outage. • This system cycles the gate to the open position one time only after AC power failure. • The convenience open system requires testing on a monthly basis to insure the batteries are fully charged and that the system is operational. • The convenience open system uses two 12-volt, 3.0 amp-hour gel-cell batteries. These batteries should be replaced every two years on average, or sooner if required. • Batteries are affected by temperature. Cold temperatures will reduce the effectiveness of the batteries. High temperatures will result in a shortened battery life. • Batteries are not covered under warranty. 5.1 Operating Mode This convenience open system consist of a control board (2340-010), motor and power supply (batteries) providing a completely redundant drive system to open the gate should a power outage occur. This system is not designed to maintain continuous gate operation; rather it provides a convenient method to open a gate ONCE during adverse conditions. If continuous gate and access control system operation is required, refer to the DoorKing Model 2000 Inverter / Backup Power System. Automatic Open after loss of AC Power Turn switch 1 ON and the system will automatically open the gate approximately 3 seconds after loss of AC power. Automatic mode is always used for for gates in general access applications such as gated communities, apartment complexes, etc. Switch 1 OFF is not used. DIP-Switches Restart Options once AC Power is restored Once AC power is restored, the system’s control board can be set to “automatically re-key” the gate operator (switch 3 ON) to establish normal operation, or can be set to require a “manual input” (switch 3 OFF) before the operator resumes normal operation. 2340 DIP-Switches 6500-065-K-7-08 29 5.2 DC System Description 5.2 DC System Description DC MOTOR NEGATIVE OUTPUT DC MOTOR POSITIVE OUTPUTBATTERY NEGATIVE INPUT BATTERY POSITIVE INPUT 24 VAC COMMON 24 VAC INPUT ACTIVATION OUTPUT RADIO POWER Not used.OPEN INPUTCOMMON Not used. Do Not Adjust Do Not AdjustTimer Not Used Charging LED 2340 DIP-Switches Gate will automatically OPEN and stay open during an AC power failure. DIP-Switch 3 setting will determine how operator will return to normal operation once AC power has been restored. + 12 V3 Amp/Hr+ 12 V3 Amp/Hr Batteries DC ON/OFFPower Switch RedBlack Red/White Red/WhiteBlack/White Diode Orange to P2 Plug on Circuit Board To Primary or Single Operator Green to Main Terminal #5 Purple to Main Terminal #3 White to Main Terminal #13 DC Motor To Secondary Operator Orange to Second Terminal #5 White to Second Terminal #7 Purple to Second Terminal #8 Green not used. 5.3 DIP-Switch Settings Switch Function Setting Description 1 Operation OFF Not Used ON Gate will automatically open when a power outage occurs. 2 Changes Open Direction OFF Set so that the gate cycles to the open direction upon loss of AC power. 3 Automatic Power-up Activation OFF When AC power is restored, an input (push button, loop, radio receiver, etc.) is required to return the gate to normal operation. ON When AC power is restored, a 1-second pulse is sent to the gate operator input to automatically restore normal operation. 4 Operator Type ON Must be in the ON position. 5 Not Used OFF 6 Not Used OFF 7 8 Not Used Not Used OFF OFF 30 6500-065-K-7-08 SECTION 6 - MAINTENANCE AND TROUBLESHOOTING SECTION 6 - MAINTENANCE AND TROUBLESHOOTING Inspection and service of this gate operator by a qualified technician should be ...