Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации DKS Enterprises, модель 6050

Производитель: DKS Enterprises
Размер: 5.9 mb
Название файла: 6050-065-L-11-08.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


All rights reserved. WARNING MOVING GATE CAN CAUSE Operate gate only when gate area is in sight and free of people and obstructions. Do not allow children to play in gate area or operate gate. Do not stand in gate path or walk through path while gate is moving. Read owner’s manual and safety instructions. SERIOUS INJURY OR DEATH CLASS CERTIFIED TO CAN/CSA C22.2 NO. 247 CONFORMS TO ANSI/UL-325 VEHICULAR GATE OPERATOR HP 53382 MODEL SERIAL VOLTS PHASE AMPS 60 Hz MAX GATE LOAD DoorKing, Inc., Inglewood, CA 6050 / 6100 SPECIFICATIONS UL325 Class of Operation Model 6050 Class I Only ; Model 6100 Class I, II, III, IV Type of Gate Vehicular Swing Gates Only Horsepower 1/2 HP Voltage / Phase 115 VAC Single-Phase Current Model 6050 1/2 HP– 4.3 Amps @ 120V ; Model 6100 1/2 HP – 5.4 Amps @ 120V Max Gate Weight Model 6050 - 400 Lbs. ; Model 6100 - 500 Lbs. Max Gate Length Model 6050 - 10 Ft. ; Model 6100 - 14 Ft. Cycles Per Hour Model 6050 - 10 Per Hour ; Model 6100 - 60 Per Hour Speed 90° in approximately 12 seconds Entrapment Protection Primary - Inherent adjustable clutch (Type C) Secondary - Inherent entrapment sensing system (Type A) and provision for connection of a non-contact sensor (Type B1) Pad Mount Kit P/N 2600-671 11” 27.75” with Convenience Open 23” Standard Post Mount Kit Arm Assembly 10.5” 13.5” 6.75” 6.25” 7.25” 6.75” 18” 6” 3” Note: 6100’s with Convenience Open: Output shaft is offset 1” from center. 9.5” P/N 2600-674 manufactured after June 30, 2008. Use this manual with the following models only: 6050-080, 6050-081, 6100-080, 6100-081, 6100-082*, 6100-083*. *Optional Convenience Open System This manual is for operators Dimensions are the same for the operator housings. Arm Assembly Distance can vary. 6” minimum.2.25” 3” 11” DoorKing, Inc. reserves the right to make changes in the products described in this manual without notice and without obligation of DoorKing, Inc. to notify any persons of any such revisions or changes. Additionally, DoorKing, Inc. makes no representations or warranties with respect to this manual. This manual is copyrighted, all rights reserved. No portion of this manual may be copied, reproduced, translated, or reduced to any electronic medium without prior written consent from DoorKing, Inc. 6050-065-L-11-08 1 TABLE OF CONTENTS SPECIFICATIONS 1 Gate Construction 4 Important Safety Instructions 4 Instructions regarding intended installation: 4 Important Notices 5 UL325 Entrapment Protection 6 Glossary 7 Swing Gate Requirements 8 Swing Gate Protection 9 SECTION 1 - INSTALLATION 10 1.1 Operator Position 10 1.2 Post Mount or Pad Mount Base Assembly 10 1.3 Underground Conduit Requirements 11-12 1.4 Pad Mount 13 1.5 Post Mount 13 1.6 Arm and Gate Bracket Installation 14 1.7 Manually Adjust the Open and Closed Gate Positions 14 1.8 Installation of Warning Signs 14 1.9 Gates Opening Wider Than 90° 15 SECTION 2 - WIRING 16 2.1 High Voltage Wire Runs 16 2.2 High Voltage Terminal Connection 16 2.3 Main Terminal Description 17 2.4 Auxiliary Terminal Description 18 2.5 Auxiliary Device Wiring 18 2 6050-065-L-11-08 2.6 Control Wiring 19 2.7 Loop Detector Wiring 20 2.8 Primary / Secondary (Dual) Gate Connection 21 SECTION 3 - ADJUSTMENTS 22 3.1 4502 Circuit Board Adjustments 22 3.2 DIP-Switch Settings 23-24 3.3 Automatic Limit Adjustment 25 3.4 Entrapment Sensing Adjustment (Adjustable Clutch) 25 3.5 Secondary Entrapment Protection System 25 SECTION 4 - OPERATING INSTRUCTIONS 26 4.1 Power and Reset Switches 26 4.2 Shutdown Conditions 27-28 Soft Shutdown Hard Shutdown 4.3 Manual Gate Operation 28-29 Emergency Vehicle Access Conditions Fail-Safe Manual Operation Manual Release SECTION 5 - OPTIONAL CONVENIENCE OPEN ADJUSTMENTS 5.1 Circuit Board 2340 Setup 30 30 5.2 DC System Description 31 5.3 DIP-Switch Settings 31 SECTION 6 - MAINTENANCE AND TROUBLESHOOTING 32 6.1 Maintenance 32 6.2 Troubleshooting 33-34 6.3 Accessory Items 35 Model 6050/6100’s Wiring Diagrams 36-45 6050-065-L-11-08 3 Gate Construction Vehicular gates should be constructed and installed in accordance with ASTM F2200; Standard Specification for Automated Vehicular Gate Construction. For a copy of this standard, contact ASTM directly at 610-832-9585; service@astm.org; or Important Safety Instructions WARNING - To reduce the risk of injury or death: 1. READ AND FOLLOW ALL INSTRUCTIONS. 2. Never let children operate or play with gate controls. Keep the remote control away from children. 3. Always keep people and objects away from gate. NO ONE SHOULD CROSS THE PATH OF THE MOVING GATE. 4. Test the operator monthly. The gate MUST reverse on contact with a rigid object or stop or reverse when an object activates the non-contact sensors. After adjusting the force or the limit of travel, retest the gate operator. Failure to adjust and retest the gate operator properly can increase the risk of injury or death. 5. Use the emergency release only when the gate is not moving. 6. KEEP GATES PROPERLY MAINTAINED. Read the owner's...

Эта инструкция также подходит к моделям:
Автоматические ворота - 6100 (5.9 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории