Войти:
Оценок - 4, средний балл: 4.5 ( )

Инструкция по эксплуатации Chamberlain, модель HEAVY DUTY, HIGH CYCLE SLIDE GATE OPERATOR SL 1000-X3

Производитель: Chamberlain
Размер: 4.27 mb
Название файла: cb2c5d66-535f-3a04-f19d-f0092c7270fa.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


PAD AND MOUNT __________________________________________________________________ 7 C. POWER WIRING ___________________________________________________________________ 8 D. LOOP DETECTORS AND PHOTO-SENSORS ____________________________________________ 8 E. TELEPHONE CONNECTION__________________________________________________________ 8 F. OTHER CONNECTIONS _____________________________________________________________ 8 G. MASTER/SLAVE INTERCONNECTION (MASTER/SLAVE SYSTEM ONLY) _____________________ 8 H. GROUNDING ___________________________________________________________________ 8 PART 2 SYSTEM INSTALLATION _______________________________________________ 9 A. GATE AND PHOTO-SENSOR LAYOUT _________________________________________________ 9 B. MOUNTING GATE OPERATOR ______________________________________________________ 10 C. QUICK DISCONNECT OPERATION ___________________________________________________ 12 D. CONNECTING POWER_____________________________________________________________ 12 E. RUNNING INPUT WIRING___________________________________________________________ 12 F. SETTING GATE OPEN DIRECTION SWITCHES S2 AND S3 ________________________________ 13 G. POWER UP PROCEDURE __________________________________________________________ 13 H. USING MANUAL CONTROLS ________________________________________________________ 14 I. SETTING LIMIT CAMS ______________________________________________________________ 15 J. GATE SENSITIVITY ADJUSTMENTS __________________________________________________ 16 K. CONNECTING INPUT WIRING _______________________________________________________ 18 L. BASIC GATE OPERATOR PROGRAMMING_____________________________________________ 18 M. POST INSTALLATION PROCEDURES_________________________________________________ 20 N. FINAL ASSEMBLY OF GATE OPERATOR ______________________________________________ 23 PART 3 GATE OPERATOR MODEL SL 1000-X3 OPTIONS __________________________ 24 LOOP DETECTOR ADD-ON BOARDS ____________________________________________________ 24 PART 4 TROUBLESHOOTING AND MAINTENANCE_______________________________25 A. TROUBLESHOOTING ______________________________________________________________ 25 B. FAULT LIST ______________________________________________________________________ 28 C. FAULTS AND THEIR CAUSES _______________________________________________________ 28 D. MAINTENANCE___________________________________________________________________ 30 APPENDIX A: SYSTEM OPERATION REFERENCE ________________________________ 33 CONTROLS, INDICATORS, INPUTS AND ADJUSTMENTS____________________________________ 33 APPENDIX B: SL 1000-X3 PARTS LIST __________________________________________ 37 GLOSSARY _________________________________________________________________ 39 FCC REQUIREMENTS ________________________________________________________ 40 NOTICE TO CANADIAN USERS_________________________________________________ 41 The LiftMaster Gate Operator Model SL 1000-X3 The LiftMaster model SL 1000-X3 Slide Gate Operator is a full-featured, commercial gate operator with master/slave wiring capability. The SL1000-X3 contains the following features: • Satisfies U.L. 325 requirements for primary (motor current) and secondary (photo) obstruction senses. • Five different open inputs are available for a variety of devices. • Dynamic motor braking limits gate overtravel. • Alternate action OPEN/CLOSE inputs. • Manual Open/Close/Stop inputs are provided for three button station. • Programmable Reclose timer. • Gate lock relay can be used for electromagnetic locks and CCTV cameras or lights. • Interrupt Bar input is included for use with edge sensors. • Master-Slave operation for two operators on bi-part gates and tandem gates. • Selectable anti-tailgate function prevents two cars from entering on one open command. • Open motor detection in case of motor thermal overload. • Maximum Run Time feature stops run-away motor in case of belt breakage. • Senses obstructions through adjustable Peak motor current sense and fixed average motor current sense. • Two separate peak motor current sense adjustments for reversing direction or stopping; one for left motion and the other for right motion. • Start-up current sense adjustment offsets initial inrush current to the motor. • Obstruction Alarm sounds the second time the gate is obstructed. • Cycle counter is able to initiate a service request call at a predetermined number. • Event recording memory keeps track of all commands and actions even during power interruptions. This is very helpful in troubleshooting the system. Can be retrieved by modem into your computer. • Automatic service request call is activated in the event of a fault or warning condition. A call can be made to any telephone or pager and will include system ID number and fault condition code. • 12-button keypad and 7-segment display to facilitate programming, service and operation. • Automatic OPEN/CLOSE and Alert Call schedules include holidays. • Two 115 VAC accessory plugs provided...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории