Войти:
Оценок - 4, средний балл: 3.8 ( )

Инструкция по эксплуатации Chamberlain, модель 1210E FS2

Производитель: Chamberlain
Размер: 4.64 mb
Название файла: 114A2680.pdf
Язык инструкции:enes
Перейти к скачиванию



Фрагмент инструкции


To Add, Reprogram or Change a Keyless Entry PIN NOTE: Your new Keyless Entry must be programmed to operate your garage door opener. USING THE LIGHTED DOOR CONTROL NOTE: These methods requires two people if the Keyless Entry is already mounted outside the garage. 1. Remove the cover from the Lighted Door Control. 2. Enter a four digit personal identification number (PIN) of your choice on the keypad. Then press and hold ENTER. 3. While holding the ENTER button, press and hold the “A” button on the Lighted Door Control. 4. Continue holding the ENTER and “A” buttons while you press the “B” button on the Lighted Door Control (all three buttons are held). 5. Release buttons when the motor unit lights blink. It has learned the code. If light bulbs are not installed, two clicks will be heard. "A" Button "B" Button USING THE MULTI-FUNCTION DOOR CONTROL 1. Enter a four digit personal identification number (PIN) of your choice on the keypad. Then press and hold ENTER. 2. While holding the ENTER button, press and hold the LIGHT button on the Multi-Function Door Control. 3. Continue holding the ENTER and LIGHT buttons while you press the push bar on the Multi-Function Door Control (all three buttons are held). 4. Release buttons when the motor unit lights blink. It has learned the code. If light bulbs are not installed, two clicks will be heard. LOCK LOCK To change an existing, known PIN If the existing PIN is known, it may be changed by one person without using a ladder. 1. Press the four buttons for the present PIN, then press and hold the # button. The opener light will blink twice. Release the # button. 2. Press the new 4-digit PIN you have chosen, then press ENTER. The motor unit lights will blink once when the PIN has been learned. Test by pressing the new PIN, then press ENTER. The door should move. To set a temporary PIN You may authorize access by visitors or service people with a temporary 4-digit PIN. After a programmed number of hours or number of accesses, this temporary PIN expires and will no longer open the door. It can be used to close the door even after it has expired. To set a temporary PIN: 1. Press the four buttons for your personal entry PIN (not the last temporary PIN), then press and hold the . button. The opener light will blink three times. Release the button. 2. Press the temporary 4-digit PIN you have chosen, then press ENTER. The opener light will blink four times. 3. To set the number of hours this temporary PIN will work, press the number of hours (up to 255), then press .. OR 3. To set the number of times this temporary PIN will work, press the number of times (up to 255), then press #. The opener light will blink once when the temporary PIN has been learned. Test by pressing the four buttons for the temporary PIN, then press ENTER. The door should move. If the temporary PIN was set to a certain number of openings, remember that the test has used up one opening.To clear the temporary password, repeat steps 1-3, setting the number of hours or times to 0 in step 3. 37 Motor Unit Assembly Parts 38 2 10 8 13 14 15 4 19a 3 9 16 12 7 18 11 17 6 6 7 DN UP Brown Wire (Down) Contact LIMIT SWITCH ASSY. Grey Wire Yellow Wire (Up) Contact Center Limit Contact Drive Gear 1a Model 1210E Model 1220E 5 1b 19b KEY PART NO. NO. DESCRIPTION 1a 31D380 Sprocket cover (Model 1210E) 1b 41A4208-2 Chain spreader (Model 1220E) 2 41C4206-2 Gear and sprocket assy. (Model 1220E) 41C4798-2 Gear and sprocket assembly (Model 1210E) Complete with: Spring washer, thrust washer, retaining ring, bearing plate, roll pins (2), drive gear and worm gear, helical gear w/retainer and grease 3 41A2817 Drive/worm gear kit w/grease, roll pins (2) 4 41B4245 Line cord 5 41A5484-7 End panel w/all labels 6 4A1344 Light socket 7 108D68 Lens 8 30B532 Capacitor - 1/2 HP 9 12A373 Capacitor bracket 10 41A3150 Terminal block w/screws 11 41D3058 Universal replacement motor & bracket assembly 12 41A5525-20 Cover KEY PART NO. NO. DESCRIPTION 13 81C253 Limit switch drive & retainer 14 41A5640 Limit switch assembly 15 41A2822-1 Interrupter cup assembly 16 41C4398A RPM sensor assembly 17 41A5483-13B Receiver logic board assy. (Model 1220E) 41A5483-12B Receiver logic board assy. (Model 1210E) 18 41C5497 High voltage wire harness assy 41C5498 Low voltage wire harness assy. 19a 41D180-1 End panel w/all labels (1220E) 19b 41D181 End panel w/all labels (1210E) NOT SHOWN 41A2826 Motor shaft bearing kit 41A2825 Opener assembly hardware kit (includes screws not designated by a number in illustration) 971-315LM Single-button remote control 12A20 3V2032 Lithium battery 29B137 Transmitter visor clip 41A2828 Manual release rope & handle assembly 114A2680 Owner’s Manual ACCESSORIES With key ring and fastening strip. 760E 99E SECURITY.® Single-Button Remote Control: Includes visor clip. 971-315LM SECURITY.® 3-Button Remote Control: Includes visor clip. 973-315MK 970-315LG SECURITY.® 3-Button Mini 1702E Outside Quick Release: Remote Control: Required for a gara...

Эта инструкция также подходит к моделям:
Автоматические ворота - 1220E FS2 (4.64 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории