STEP 5 GATE BRACKET INSTALLATION Activate push button on the side of the control box and extend the actuator until it stops (PULL TO OPEN only, leave actuator retracted for PUSH TO OPEN). WARNING: Do not let extension tube rotate as it extends. Do not insert fingers or tools in the hole at the end of the extension tube Align the hole in the end of the actuator extension tube with the holes in the gate bracket and locate gate bracket mounting position with the gate in the closed position. Weld or bolt the gate bracket to the gate using 3/8” bolts, lock washers, and nuts. Tip: Tack weld or C clamp at first if uncertain about location. Run the unit through a complete cycle to insure proper operation then mount permanently . Bolt the actuator to the gate bracket as shown. Bracket should attach 52” - 54” from the center of the hinge. 1/2” x 3” Bolt 1/2” Lock Nut 1/2” Washer (2 places) Extend Limit Screw Retract Limit Screw 9 635/636 CONTROL BOARD CONNECTIONS 8 6 4 2 7 5 3 1 8 Pin White Connector (two on 636 Master & Slave) 1 ORANGE - Open Limit Input (Normally open unless gate is opened) 2 WHITE - Close Limit Input (Normally open unless gate is closed) 3 BLACK - Motor - Positive during open cycle, Negative during close cycle 4 RED - Motor - Negative during open cycle, Positive during close cycle 5 GREEN - Ground (Limit Switch Common) 6 Ground Not used 7 BLACK - Ground -Battery Negative 8 RED - Battery Positive (+12 VDC) MASTER 7 Pin Black Connectors 1 Edge 1 Input 2 Edge 2 Input 3 Ground 4 Ground 5 Stop Input (N/C) 6 Close Input (N/O) 7 Open Input (N/O) 123 3 Button Control 8 Ground 9 Ground 10 Free Exit Input (Open only for telephone entry, probes, etc.) 11 Ground 12 Under Gate or Shadow Loop Input 13 Ground 14 Safety Loop or Photo Beam Input 3 Pin Black Connectors (3) GND Ground INP Input (Activates gate when momentarily connected to ground) 12V +12 Volt Output (For powering options -3 Amps Max.) Emergency Bypass Connector Used when the control board is not functioning. Unplug the motor harness from the Master (or Slave) Connector and momentarily insert into the Emergency Bypass Connector to open the gate. In the event the motor is not disconnected quickly enough, the blue 15 amp fuse will protect the circuit board from damage and should be replaced when the 10 original problem is fixed. 635/636 CONTROL BOARD ADJUSTMENTS OFF ON PROGRAM SWITCHES Factory Description Setting #1 ON TIMER TO CLOSE -Automatically closes gate ON - Close timer enabled OFF - Close timer disabled #2 OFF CURRENT SENSITIVITY OPTION -Delays current sensing from start ON - 4 second delay OFF - 2 second delay #3 ON TIMER TO CLOSE OPTION ON - timer to close works only when open limit switch is activated OFF - timer to close works from any open gate position #4 OFF DUAL CONTROL SLAVE OPTION ON - disables slave side of dual board OFF - enables slave side of dual board #5 OFF DUAL CONTROL MASTER OPTION ON - disables master side of dual board OFF - Enables master side of dual board #6 OFF MAXIMUM RUN TIMER OPTION ON - stops and reverses gate if run timer times out before closing OFF - stops gate if run timer times out before closing #7 ON MAXIMUM RUN TIMER VALUE ON - 40 seconds OFF -20 seconds #8 ON TIMER TO CLOSE VALUE ON - 20 to 70 seconds (adjustable) OFF - 10 to 35 seconds (adjustable) #9 OFF OPEN, STOP, CLOSE CONTROL ENABLE ON - allows for open, stop, close unit (optional) to operate gate OFF - normal operation (If 9 is on, terminals 4 & 5 must be normally closed for proper operation.) TIMER TO CLOSE ADJUSTMENT Rotate clockwise to increase time before gate closes. Rotate counter clockwise to decrease time before gate closes. If program switch #3 is on, the gate must activate the open limit switch in order for the timer to close to operate. CURRENT SENSITIVITY Rotate clockwise to decrease sensitivity (more force). Rotate counter clockwise to increase sensitivity (less force). WARNING: The CURRENT SENSITIVITY should be adjusted to prevent injury in the event of someone being entrapped in the gate. This feature should be periodically tested to assure proper operation. Refer to SAFETY PRECAUTIONS. LED ENABLE Enables LEDs for installation and troubleshooting (must be de pressed to observe LEDs). TIMER TO CLOSE CURRENT SENSITIVITY LED ENABLE Fuses There are 4 standard automotive type fuses on the 635/636 circuit board. The EMERGENCY BY-PASS plug is protected by a 15 Amp fuse. The remaining three fuses (one for each of the 12 Volt outputs) are 3 amp. 11 PUSH TO OPEN INSTALLATION 12 Both measurements are taken from the center of the hinge. 11” 6” Direction of opening Gate (closed) Hinge post Top View Vertical position of pivot arm (s) Pivot arm must be level 1/2” Hinge post Center Line of attachment point for gate bracket Front View PIVOT ARM (s) INSTALLATIONSTEP 1 Location of pivot point Rewiring actuator (s) for push to open Must be re-wired for proper operation Strip back 6” of black sleeve from connector end of the actuator cable. Cut and reconn...
Эта инструкция также подходит к моделям:Автоматические ворота - SWING GATE OPERATOR 1600 (1.89 mb)