Войти:
Оценок - 3, средний балл: 3 ( )

Инструкция по эксплуатации Quantum, модель 3314

Производитель: Quantum
Размер: 720.73 kb
Название файла:
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


IMPORTANT: You MUST change the Transmitter security code prior to programming the device to the power head unit. WARNING: During programming the garage door may operate. Keep people and objects clear of the moving door to prevent door damage or possible personal injury. Changing the Transmitter Code 1. Press and hold the Transmitter’s large button for approximately 10 seconds until Transmitter’s LED begins to blink rapidly. Release button (LED will turn off). 2. Press and hold the Transmitter’s large button again (LED will light) for approximately 5 seconds until the Transmitter’s LED begins to blink rapidly. Release button. 3. LED will blink on and off three times indicating a successful security code change. 16 Programming Transmitter to Power Head Unit Note: Do not press any button on the Transmitter until instructed 1. Press the PROGRAM Switch button located on the garage door power head unit once. The red PROGRAM STATUS light on the motor power head unit and overhead lamp will turn on and remain lit for one minute, indicating that it is ready to learn the Transmitter. 2. Press the button on the Transmitter you wish to use to operate the door. The PROGRAM STATUS light on the power head will turn on and off three times indicating a successful learn. 3. Press the same button on the Transmitter once more to confirm operation. The opener will turn on and move the door. At this point you will be able to activate the opener. Battery: If the LED (light) on Transmitter does not turn on when a button is pressed, repeat “changing the transmitter code” operation. If LED fails to light replace battery. To change battery, insert a coin in the coin slot and twist coin to access battery compartment. Some transmitters use two CR2016 or equivalent batteries while others use a single MN21 or equivalent battery. Snap case together after replacing. Step 25: Connecting Cushion Arm to Trolley Activate opener to bring trolley to factory pre-set close limit (See illustration). Cushion arm assembly consists of the door arm tube section and door arm rod, which are packed separately. To assemble, screw the door arm rod into the door arm tube in a clockwise direction approximately ten turns. Connect cushion arm assembly into trolley with open end of rod hook facing motor. Attach warning tag and red pull knob to red release cord connected to trolley. Step 26: Setting Trolley Close Position Activate opener to confirm trolley close position is 9” to 10” between the inside face of the door and the solid cushion arm rod. If adjustment of the trolley position is necessary, use the CLOSE TRAVEL ADJUSTMENT knob located on the bottom of the motor power head unit. A 1/4 turn equals approximately 1” of trolley movement; turn clockwise to move forward; counterclockwise to move back. 17 Step 27: Connecting Door Arm to Door Door Mounted Bracket Visually align cushion arm connecting hole with middle hole of door bracket by rotating tube section in appropriate direction. Release trolley (cushion arm attached) with manual release cord and pull trolley a few inches toward motor. Now rotate cushion arm tube section 2 turns counterclockwise to provide a cushion when door is closed or encounters an obstruction. Align connecting hole in Step 27: Connecting Door Arm to Door Door Mounted Bracket Visually align cushion arm connecting hole with middle hole of door bracket by rotating tube section in appropriate direction. Release trolley (cushion arm attached) with manual release cord and pull trolley a few inches toward motor. Now rotate cushion arm tube section 2 turns counterclockwise to provide a cushion when door is closed or encounters an obstruction. Align connecting hole in cushion arm to middle hole in door bracket; insert 3/8” dia. bolt and tighten locking nut, allowing for free pivoting of arm. Note: Do not over tighten locking nut, as this will cause binding between cushion arm and door bracket. Step 28: Setting Door Close Travel Plus “Contact Obstruction Sensing” Test With wall control up/down button, activate door to full open position; reactivate to close position. The door should stop on the floor with the cushion arm and the bottom door seal slightly compressed. If the door reverses off the floor, turn close travel knob 1/4 turn “less”. If door is not completely closed, turn travel knob 1/4 turn “more”. Repeat if necessary. IMPORTANT! Test “Contact Obstruction Sensing Feature” After installing opener, the door must reverse when it contacts a 1 inch high object on the floor Activate the door to the full, open position and place a 1” (25mm) solid test obstacle on the floor under the garage door. Activate the door to the closed position. The door should reverse upon contact with the 1” obstacle. If door stops on the 1” obstacle, adjust the close travel knob 1/4 turn “more” until door reverses upon contact with obstacle. Repeat if necessary. When the door reverses, remove the test object and run the full cycle of open and close of the door. Do...

Эта инструкция также подходит к моделям:
Автоматические ворота - 3214 (720.73 kb)
Автоматические ворота - 3414 (720.73 kb)
Автоматические ворота - 3316 (720.73 kb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории