Войти:
Оценок - 3, средний балл: 3.7 ( )

Инструкция по эксплуатации GTO, модель Mighty Mule 352

Производитель: GTO
Размер: 2.9 mb
Название файла: 352_Insrts_8-8-08.pdf
Язык инструкции:en
Перейти к скачиванию



Фрагмент инструкции


AUX OUT SOLARPANEL18VAC LINK RCVR GRN BLK RED EXIT SAFETY EDGE CYCLE COMMON Mighty Mule 352 Connecting Accessories Connecting Accessories CHARGING POWER RF AUX OUT SOLAR PANEL 18VAC RCVR GRNBLKREDEXITSAFETYEDGECYCLECOMMON LINK GTO Photo Beams GTO Loop Detector GTO Automatic Lock Mighty Mule Push Button Control According to Application Mighty Mule Vehicle Sensor Refer to Vehicle Sensor manual for additional connections. Edge Sensor ON 10DIP NO COM NC V + V – LOOP LOOP LOOPNOTE:Connections are for typical applications. There may be additional connection options for applications that are not illustrated here. 8 10 10 1010 7 10 6 Mighty Mule Keypad GTO Universal Receiver 6 7 9 10 1 2 ABC3 DEF4 GHI5 JKL6 MNO7 PRS8 TUV9 WXY0 8 1 2 3 4 7 8 9 105 6 1 10 10 10 1 1 1 10 10 Ch 2 Wireless Wand Ch 1 Remotes Red Blue Black Shield Yellow Red + Power Black - Power 6 9 10 AUTOMATIC GATE LOCK® ELECTRONIC SECURITY LOCK 2 1 NOTE: When connecting Automatic Lock make sure DIP #4 is set to off. Mighty Mule 352 Master Opener below. Second Opener The battery harness and communication cable must be routed down the sides of the opener and flatly out of the slot in the back of the opener. It is IMPORTANT that the wires lay flat and run inside the routing pins at the back of the opener and out the slot without being pinched when the control board access cover is replaced. See the illustrations to the right and below. Wire Routing Routing Pin Neatly arrange both wires to lay ON/OFF– o Battery Harness Wires Transformer or Solar Wires Receiver Wires Communication Cable (LINK) Accessory Wires Neatly arrange all wires to lay flat as they come out of the opener. Mighty Mule 352 Master Opener Wire Routing Routing Pin 20 amp fuse 20 The master opener's battery harness wire has an in-line 20 Amp fuse that must be placed inside the opener prior to closing the access panel. The illustration to the right shows the best placement for the battery harness wire, connector and in-line fuse, communication cable, receiver wire, transformer or solar panel and any accessories that have been installed. All wires must be routed down the sides of the opener and flatly out the slot in the back of the opener. It is IMPORTANT that the wires lay flat and run inside the routing pins at the back of the opener and out the slot without being pinched when the control board access cover is replaced. See the illustrations to the right and Wire Slot To avoid stripping screw holes - tightening screws by hand with a hand held screwdriver is recommended. If you have any questions please call GTO Technical Service at 1-800-543-1236. ON/OFF– o Battery Harness Wires Communication Cable flat as they come out of the opener. Mighty Mule 352 Second Opener Routing Wires Through The Access Panel Mighty Mule 352 Final Step When everything has been connected to the opener... Replace the control board access cover. If you were working with the opener with the control board access facing up, remove the opener arm from both mounts and remount it in the upright position (control board cover facing down). Failure to remount opener in the up right position will allow water to enter the opener and cause damage to the opener control board. Mighty Mule 352 Push to Open Installation Determining The Mounting Position of The Post Bracket Assembly Swinging gates shall not open into public access areas! "Push-to-Open" gates open out from the property. Push-to-Open Brackets are required for this type of installation (see Accessory Catalog). If you have pull-to-open gates (gate opens into the property), return to page 13; step 3. In a PUSH-TO-OPEN installation the opener is installed while the gate is in the closed position. Step 1 With the gate in the closed position (up to 110. from its open position), and the opener fully retracted, adjust the post bracket assembly and gate bracket until the opener is level. While holding the opener level, use C-clamps to temporarily keep the post bracket assembly and gate bracket in their respective positions on the fence post and gate. ........................................................................................................................................................................................................................Post Bracket Assembly........................ IMPORTANT: While determining the mounting point for the post pivot bracket assembly, be sure that the position allows for minimum 2 inches of clearance between the gate and the opener in both the open and closed positions, as shown in the diagrams below. This clearance will give the opener the most efficient leverage point for opening and closing the gate and more importantly provides the least possible pinch area. Step 2 After verifying that you have the best position for the post pivot bracket, insert the Gate in the Open Position 5/16" x 1 3/4" bolt through the aligned holes Pinch Area (gray) of the post bracket and post pivot bracket and fasten it with the 5/16" washer ...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории