Фрагмент инструкции


CAUTION NOTE: Set Close Travel Limit before setting Open Travel Limit for unit to operate normally. Unless limits are being reset do not press set limit buttons. PN# 37026500123 02/26/2010 REV. 1 CARRIAGE LOCK The Carriage Lock can be manually engaged or disengaged. • To disengage Carriage Lock – Pull handle downward opener power head. • To engage Carriage Lock – Pull handle towards door. UNLOCKDOORLOCKTO RECONNECT PULL TOWARD DOOR TO RELEASE PULL TOWARD THE OPENER FIG. 6-3 Engage/Disengage Carriage Lock. KEYED EMERGENCY RELEASE (PURCHASED SEPARATELY) Obtain standard emergency release kit and remove S-hook from the cable end that attaches to the opener carriage. 1. Attach the emergency release cable loop end to the opener carriage as shown (FIG 6-4). Properly connecting the release cable to the carriage fitting will enable the correct carriage release action for the opener. WARNING 2. Follow the remaining installation instructions for the standard emergency release kit. 3. Test for correct operation of emergency release kit. Keyed Emergency Release Operation Instructions • Place key in slot. • Rotate and hold key while lifting garage door 1 to 2 inches. • Release key and continue opening garage door. NOTE: The next normal operation of the opener orfully closing garage door manually will re-engagethe emergency release mechanism. FIG. 6-4 Emergency release cable to carriage. UP/DOWN FORCE UP/DOWN FORCE CLOSE 1. By turning the "Close Force Control" clockwise, the DOWN force can be increased. By turning the "Close Force Control" CLOSE counterclockwise, the DOWN force can be decreased. Set the DOWN force level at the minimum force required to close door without reversing. 2. Once the desired level is selected, this stores the necessary force level for the DOWN direction in memory. OPEN 3. By turning the "Open Force Control" clockwise, the UP force can be increased. By turning the OPEN "Open Force Control" counter-clockwise, the UP force can be decreased. Set the UP force level at the minimum force required to open door without stopping. 4. Once the desired level is selected, this stores the necessary force level for the UP direction in memory. ERASE - OPEN/CLOSE TRAVEL LIMIT 1. Press and hold both of the "SET" buttons ( SET& SET) together until the green indicator light blinks (about 5 seconds). 2. All close and open travel limit settings are erased. Then follow the steps above to reprogram close and open travel limits. NOTE: The opener will not close the doorautomatically unless the Safe-T-Beam® System isinstalled. CONTACT REVERSE TEST The force adjustments and limit switch settings MUST BE COMPLETED before testing. 1. Testing. • Open garage door using Wall Control. – Place a 2" x 4" board (laid flat) under center of garage door opening (FIG. 6-6). • Close door using Wall Control. • When door contacts board, the door must stop (within 2 seconds) and reverse direction returning to open position. 2. Adjustment. • If the door does not properly reverse. – Check to see if door has "close" limit programmed. It should not have reached its "close" limit before hitting board. – If the door STOPS but does not reverse, decrease "CLOSE FORCE" control CLOSE setting slightly (turn it counter-clockwise). • Test again. Repeat as necessary until door reverses upon contacting board. FIG. 6-6 2 x 4 under center of door opening. OPENFORCECLOSEDown Force Control Adjustment Up Force Control Adjustment ROTATE CLOCKWISE ROTATE COUNTER-CLOCKWISE (Increasing Force) (Decreasing Force) FIG. 6-5 Force Control Adjustment. PN# 37026500123 02/26/2010 REV. 1 PROGRAMMING REMOTE CONTROLS7 A moving door can cause serious injury or death. 1. Keep people clear of opening while door ismoving. 2. Do NOT allow children to play with opener, including wall button, remote control, orWireless Keypad. 3. During programming, the door opener couldbegin to run, so keep people and objects away from the moving door and its parts. To keep thedoor from moving, close the door anddisconnect it from the Opener by pulling theEmergency Release. WARNING PROGRAMMING REMOTE CONTROLS7 A moving door can cause serious injury or death. 1. Keep people clear of opening while door ismoving. 2. Do NOT allow children to play with opener, including wall button, remote control, orWireless Keypad. 3. During programming, the door opener couldbegin to run, so keep people and objects away from the moving door and its parts. To keep thedoor from moving, close the door anddisconnect it from the Opener by pulling theEmergency Release. WARNING NOTE: For remote control locate Box 3. 1a. Single Button Remote Programming. NOTE: This opener can learn up to 7 transmitterbuttons. LEARN . Locate “Learn Code” button and indicator LED on the power head CODE (Fig. 7-1). . Press and release “Learn Code” button. – Indicator LED will blink RED at a rate of twice per second. . Within 30 seconds, push remote control button once. – Indicator LED will stop blinking and stay ON. . Press remote control butto...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории