Войти:
Оценок - 2, средний балл: 3 ( )

Инструкция по эксплуатации Genie, модель BeltLift 1024

Производитель: Genie
Размер: 14.87 mb
Название файла:
Язык инструкции:enesfrda
Перейти к скачиванию



Фрагмент инструкции


• It must be away from any moving parts. (You should NOT be able to reach the garage door while standing at Wall Button.) • Wall Button board screw connections are polarized, (+) positive and (-) negative. 2a. Wiring (If pre-wired). • Locate Wall Button pre-wired wire ends (Fig. 3-1). (They should be located within the guidelines mentioned above.) • Split and strip ends of wire (Fig. 3-2). • Fasten wire to Wall Button board screws on back of Wall Button. – Striped wire to the + (plus) terminal. – White wire to the - (minus) terminal. 2b. Wiring (If NOT pre-wired). • Pick a convenient location for mounting Wall Button using the guidelines mentioned above (Fig. 3-1). • Run wire from Wall Button to power head (Fig. 3-1). • Split and strip ends of wire (Fig. 3-2). • Fasten wire to control board screws on back of Wall Button. – Striped wire to the + (plus) terminal. – White wire to the - (minus) terminal. FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM FIG. 3-2 Splitting and stripping. FIG.3-1 Wall Button wire routing Wire from power headto wall control. Wall control "Entrapment" warning label Separateentry door EXAMPLE ONLY! This is an example of wire routingwhen NOT pre-wired. Your wire routing may be different. 1/2" 2" or or B W PN# 36420Supplement, 10/27/2008 3.Securely fasten wires. • Securely fasten wires to ceiling and wall using insulated staples provided. – Use insulated staples. – Staples should be snug only. Insulated • If rear cover is attached to power head, Staple remove it. • On power head: – Route Wall Button wires through wire guide. – Split and strip ends of wire (Fig. 3-2 on previous page). – Insert wire into terminal holes and lightly press in the orange locking clips above each terminal hole. (You can use a pencil or small screwdriver to comfortably press in locking clips.) The white wire into #1 terminal hole and striped wire into the #2 terminal hole. – Confirm wire lock by lightly tugging on the wire. The wire should remain in the terminal hole. • Do NOT install rear cover yet. 4. Mounting. • Fasten Wall Button to wall with 2 screws (provided) (Fig. 3-4). • Remove protective backing from "Entrapment" warning label (Fig. 3-5). The "Entrapment" label is located in the center of this manual. – Stick label on wall near Wall Button. +– P B Infared Sensor 123456 (Power Head With Rear Cover Removed) 1234 Terminal Holes Locking Clips 56 FIG. 3-3 Insert wires. FIG. 3-4 Mounting Wall Button. FIG. 3-5 Mounting Entrapment warning label. PN# 36420Supplement, 10/27/2008 SAFE-T-BEAM® SYSTEM INSTALLATION 4 There should be no electrical power to the opener while installing Safe-T-Beam® wires. If you have plugged in the power cord—UNPLUG IT NOW! WARNING SAFE-T-BEAM® SYSTEM INSTALLATION 4 There should be no electrical power to the opener while installing Safe-T-Beam® wires. If you have plugged in the power cord—UNPLUG IT NOW! WARNING NOTE: The opener will not close the doorautomatically unless the Safe-T-Beam® System isinstalled. NOTE: For Sensors, screws, wire, and insulatedstaples locate items and Bag 8 from Box 3. 1. Mounting brackets. • Mark both sides of garage door frame or wall no higher than 6" and no lower than 5" above floor (Fig. 4-1). • Hold bracket against door frame or wall. – Check if brackets extend out from wall far enough, so tongue of bracket is beyond door, tracks or any door hardware. – If not: a) Mounting bracket extensions are available through an authorized Genie® Dealer. b) Blocks of wood, etc. may be substituted for extensions. • Center bracket on your mark (Fig. 4-2). • Fasten each with 2 screws (Fig. 4-2). NOTE: Mounting brackets can be attached to thefloor or concrete rim using concrete anchors(not provided). 2. Mounting Safe-T-Beam® Source (Red LED) and Sensor (Green LED). • If garage has only one garage door. – Determine which side of garage receives most direct sunlight (Fig. 4-4). – Red LED should always be on sunny side whenever possible (Fig. 4-4). • For multiple doors. – Preventing crossed signals is critical. – Place source and sensor modules on adjacent doors facing in opposite directions (Fig. 4-4). NOTE: To help prevent interference from sun, Safe-T-Beam® sensor with Green LED may beplaced further away from the door opening, though extended no further out from the wall, where it will spend more time in shadow. • Slide source/sensor onto tongue of bracket until it clicks into place (Fig. 4-3). 3a. Wiring (If NOT pre-wired). • Route wire from Safe-T-Beam® sensors to power head using method shown in (Fig. 4-5a). • Securely fasten wires to wall and ceiling as you go (Fig. 4-6 on next page). – Use insulated staples. – Staples should be snug only. Insulated Staple FOR HELP-1.800.354.3643 OR WWW.GENIECOMPANY.COM FIG. 4-1 Mark door frame. FIG. 4-2 Mounting brackets. FIG. 4-3 Attach sensors to brackets. slide bracket tongue mark center of bracket FIG. 4-4 Safe-T-Beam® source and sensor locations. SUN ONE DOOR GARAGE THREE DOOR GARAGE RED LED RED LED GREEN LED RED LED GREEN LED...

Эта инструкция также подходит к моделям:
Автоматические ворота - BeltLift 1022 (14.87 mb)
Автоматические ворота - BeltLift 1042 (14.87 mb)

Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории