Before using these docking stations, verify they have been installed with the latest firmware. Refer to Refer to the MVP-7500/8400 Operation/Reference Guide (available online at for more information. Once an MVP is connected to a docking station, charging is first applied to any MVP-BP batteries found within the panel’s rear battery compartment and then to any batteries inserted within the docking station. MVP-TDS Table Docking Station for MVP Panels MVP-TDS Table Top Docking Station Installing an MVP-BP Battery into an MVP-TDS The MVP-TDS connects directly to a PSN4.4 power supply and provides both power and communication to docked MVP panel. The MVP-TDS can charge batteries in its own battery compartments, as well as those within the MVP panel. 1. Raise the rear connector cover to expose the battery compartments and connectors. 2. Slide the MVP-BP into the battery compartment (AMX label up) until the connector makes contact with the battery pins at the end of the battery slot. 3. Repeat these steps for any additional MVP-BP batteries. 4. The status of the connected batteries are reflected on the panel’s Batteries page and the LEDs on the docking station. A completely discharged battery requires one full charge cycle from within battery compartment #1. Refer to FIG. 2 on page 2 for locations. MVP-TDS Table Docking Station for MVP Panels MVP-TDS Table Top Docking Station MVP-TDS Table Docking Station for MVP Panels Upgrading the Docking Station Firmware Upgrading the Docking Station Firmware The following accessory devices are firmware upgradeable: .. MVP-TDS Table Top Docking Station (FG5965-10) .. MVP-WDS Wall/Flush Mount Docking Station - Black (FG5965-11) .. MVP-WDS Wall/Flush Mount Docking Station - Silver (FG5965-21) This device is not given a unique device number which would ordinarily appear within the Online Tree tab of NetLinx Studio. It appears as a battery base below the target panel which it is a part of as seen below in FIG. 1. TDS/WDS (station version) Target Panel Device # NetLinx Studio Online Tree tab Accessory’s corresponding firmware page FIG. 1 Location of Firmware version information within NetLinx Studio The only way to upgrade the firmware of these accessory items is to send the accessory’s firmware through a target panel. Its this panel’s device number which is entered within the Send to NetLinx Device transfer dialog in Studio. Step 1: Prepare the Docking Station for firmware transfer via USB Before beginning with this section: .. Verify the MVP is securely attached to the docking station and communicating properly. .. Verify that the panel is communicating from the mini-USB port to the Virtual NetLinx Master (VNM). 1. Configure the NetLinx Master for IP communication. Refer to the MVP-7500/8400 Operation/ Reference Guide (available online at for information. 2. After the panel powers-up, press and hold the two lower buttons on both sides of the display for 3 seconds to continue with the setup process and proceed to the Setup page. 3. Press the Batteries button to open the Batteries page (FIG. 2). MVP-TDS Table Docking Station for MVP Panels Upgrading the Docking Station Firmware FIG. 2 Batteries page Displays the current docking station firmware version The docking station firmware is shown on the right of the Batteries page. Verify you have downloaded the latest firmware file from and then save the Kit file to your computer. Step 2: Upgrade the Docking Station firmware via USB 1. Configure the panel for a USB Connection Type. 2. Prepare NetLinx Studio for communication to the panel via a Virtual Master. Refer to the MVP-7500/8400 Operation/Reference Guide (available online at for information on configuring communications on the panel. 3. After the Communication Verification dialog window verifies active communication between the Virtual Master and the panel, click the OnLine Tree tab in the Workspace window to view the devices on the Virtual System. The default System value is one. 4. Right-click on the System entry and select Refresh System to re-populate the list. Verify the panel appears in the OnLine Tree tab of the Workspace window. The default Modero panel value is 10001. 5. Locate the latest firmware file from the > Tech Center > Downloadable Files > Firmware Files > Modero Panels firmware (MVP Docking Stations: MVP-TDS/WDS) section of the website. 6. Click on the desired Kit file link and after you’ve accepted the Licensing Agreement, verify you have downloaded the Docking Station Kit file to a known location. 7. Select Tools > Firmware Transfers > Send to NetLinx Device from the Main menu to open the Send to NetLinx Device dialog (FIG. 3). Verify the panel’s System and Device number values match those values listed within the System folder in the OnLine Tree tab of the Workspace window. 8. Select the docking station’s Kit file (ending in VXX.kit) from the Files section (FIG. 3). 9. Enter the Device number ass...