|
Фрагмент инструкции
• If mounting into the BB-6X-DSW, bend the flanges back as far as they can go. 6. Use four standard drywall screws (length should not exceed drywall thickness by more than 1/2 inch) to secure the mud ring plate to the rest of the assembly. The screws pass through the clearance holes in the PMK-6X-DSW (or BB-6X-DSW) and are secured in the extruded holes of the adjustment plates. 7. Verify that the mud ring plate is level. NOTE: Do not overtighten screws. Doing so may over-dimple or rip the mud ring plate. 8. Use a #2 Phillips screwdriver and tighten the drywall screws by hand so that they slightly dimple into the holes in the mud ring plate. 9. Apply drywall joint compound as needed to finish the cutout. Avoid covering the four tapped mounting holes. 10. Run the necessary cables for the TPS-6X-DSW and secure them behind the drywall. 11. When dry, the wall mount docking station can be installed using the four tapped holes in the PMK-6X-DSW. Refer to the latest revision of the TPS-6X-DSW Operations and Installation Guide (Doc. 6708) for installation instructions. Refer also to the comprehensive illustration below. TPS-6X-DSW Mounting Using MMK-6X-DSW – Exploded View TPS-6X-DSWSCREW (4) #06-32 1 1/2" PAN HEAD (2007254) DRYWALLDRYWALL SCREWS (NOT INCLUDED) SCREW LENGTH SHOULD NOT EXCEED DRYWALL THICKNESS BY MORE THAN 1/2" (13 MM). PMK-6X-DSWNOTE:REQUIRED ADJUSTMENT PLATES AND PUSH-ON FASTENERS NOT SHOWN. MUD RING PLATE(2022809) WMKM-6X-DSW Procedure This section provides the necessary steps for the assembly and installation of the WMKM-6X-DSW into a wall. Review the procedure and complete the steps in the order provided. The only tools or materials required and not supplied are a drywall saw or equivalent, a level, four standard drywall screws, #2 Phillips screwdriver and tools/material to apply drywall joint compound. CAUTION: Allow an air gap of at least 12 inches (30.48 cm) in the wall cavity above and below the TPS-6X-DSW for heat dissipation. 1. Insert the two pins on one adjustment plate into the top two outer holes on the mounting plate, as shown in the illustration below. Create the Adjustment/Mounting Plate Assembly ADJUSTMENT PLATE (2) (2017631) MOUNTING PLATE(2022811) PUSH ON FASTENER (4) (2004121) 2. Slide a push-on fastener over each pin on the adjustment plate to loosely secure the adjustment plate and the mounting plate. Do not push the push-on fasteners all the way down onto the pins. Slide them on enough to keep the adjustment plate and mounting plate as one adjustment/mounting plate assembly. 3. Use the second adjustment plate and repeat steps 1 and 2 using the lower two holes on the mounting plate. 4. Locate an area on the wall that is free of miscellaneous wiring and studs. 5. Make a small hole near the middle of the designated site; verify that the location is suitable. NOTE: Make the cutout as level as possible. The mounting plate allows for only minor leveling adjustments. 6. Use the drywall saw or equivalent and the included drywall cutout template to produce an accurate and level cutout in the drywall. 7. Insert the symmetrical mud ring plate into the opening, as shown in the illustration below. Insert Mud Ring Plate into Opening DRYWALLMUD RING PLATE(2022809) DRYWALL SCREWS(NOT INCLUDED) SCREW LENGTH SHOULD NOT EXCEED DRYWALL THICKNESS BY MORE THAN 1/2" (13 MM). 8. Carefully pass the adjustment/mounting plate assembly through the opening and rest the assembly against the interior surface of the drywall. Verify that the adjustment plates are between the mounting plate and the drywall. 9. When the adjustment/mounting plate assembly is in position, bend the top two flanges of the mud ring upward (approximately 90 degrees) and the bottom two flanges downward (approximately 90 degrees). Refer to the illustration on the following page. NOTE: Adjustment/mounting plate assembly will have a slight play; this is normal. It allows for minor adjustments to the entire assembly during installation. Bend Flanges – 1 of 4 Flanges Bent BACK OF DRYWALL 10. Use four standard drywall screws (length should not exceed drywall thickness by more than 1/2 inch) to secure the mud ring plate to the adjustment/mounting plate assembly. The screws are secured in the extruded holes of the adjustment plate and pass through the clearance holes in the mounting plate. 11. Verify that the plate is level before tightening. NOTE: Do not over tighten screws. Doing so may damage the plate. 12. Use a #2 Phillips screwdriver and tighten the drywall screws by hand so that they slightly dimple into the holes in the mud ring plate. 13. Run the necessary cables for the TPS-6X-DSW and secure them behind the drywall. 14. Apply drywall joint compound as needed to finish the cutout. Avoid covering the four tapped mounting holes. 15. When the joint compound is dry, the wall mount docking station can be installed using the four tapped holes in the mounting plate. Refer to the latest revision of the TPS-6X-DSW Operations and Installation ...
Эта инструкция также подходит к моделям:Акустика - MMK-6X-DSW (578.88 kb)