Wt. (pounds) RLS28 18.75 18.69 22.88 8.50 5.50 13.88 6.44 31.88 4.25 6.63 1.50 95 RLS38 18.75 18.69 22.88 8.50 5.50 13.88 6.44 31.88 4.25 6.63 1.50 99 RLS50 18.75 18.69 22.88 8.50 5.50 13.88 6.44 31.88 4.25 6.63 1.50 101 Burner Model Number A B C D E F G H I L M N O Approx. Wt. (pounds) RLS70 27.50 11.38 16.13 21.88 33.13 9.88 7.06 16.94 45.75 8.44 5.31 8.75 2.00 159 RLS100 28.88 12.75 16.13 21.88 33.13 9.88 7.06 16.94 45.75 8.44 5.31 8.75 2.00 165 RLS130 28.88 12.75 16.13 21.88 33.13 9.88 7.44 16.94 45.75 8.44 5.31 8.75 2.00 170 Part No. 550-142-023/0508 Weil-McLain 88 Water and Steam Boilers — Series 2 — For Gas, Light Oil, & Gas/Light Oil-Fired Burners Burner specifications and settings Table 1 Burner data — #2 Fuel oil/Natural gas — Modulating Boiler Model Number Burner Model Number Pressure Drop Thru Gas Train Manifold Pressure Gas Pressure Required at Gas Control Inlet Gas Pilot Pressure Combustion Head Setting Combustion Air Indications Servo Motor Cam Position Settings Oil Nozzles Oil Pressure Fuel Independent Motor Driven 3450 RPM Inches W.C. Inches W.C. Inches W.C. Min Inches W.C. Max Inches W.C. Low Fire High Fire Blue Orange Red 1 2 3 4 5 6 Qty. GPH @ 100 PSIG Brand Type Spray Angle Supply PSIG Suntec Type Gear GPH 488R RLS28 1.19 4.60 5.79 14 5.0 1 23 67 22 42 70 1 1 2.75 2.50 Delavan B 70° 60° 180 AL65C 22.0 488 RLS28 1.19 4.85 6.04 14 5.0 2 23 67 22 42 70 1 1 3.00 2.50 Delavan B 70° 60° 180 AL65C 22.0 588 RLS38 1.88 5.85 7.73 14 5.0 1 20 50 19 41 55 1 1 4.00 3.50 Delavan B 60° 60° 167 AL65C 22.0 688 RLS50 2.09 5.88 7.97 14 5.0 3 32 90 32 50 90 1 1 4.50 5.00 Delavan B 60° 60° 173 AL65C 22.0 788 RLS50 2.12 5.85 7.97 14 5.0 5 35 83 35 45 83 1 1 5.50 6.00 Delavan B 60° 80° 168 AL65C 22.0 888 RLS70 3.04 4.36 7.40 14 7.5 0 1.5 6.0 — — — 130 0 40 120 30 100 1 1 6.50 6.50 Delavan B 90° 60° 180 AJ4CC 52.5 988R RLS70 3.18 4.14 7.32 14 7.5 0 1.8 7.5 — — — 130 0 40 120 27 100 1 1 7.50 7.25 Delavan B 90° 60° 180 AJ4CC 52.5 988 RLS70 3.18 4.39 7.57 14 7.5 1 1.8 7.5 — — — 130 0 40 120 27 100 1 1 7.50 7.50 Delavan B 60° 60° 180 AJ4CC 52.5 1088R RLS70 3.35 3.68 7.03 14 7.5 3 1.9 9.0 — — — 130 0 32 120 45 100 1 1 8.50 7.25 Delavan B 60° 60° 209 AJ4CC 52.5 1088 RLS100 3.35 3.93 7.28 14 7.5 4 1.9 9.0 — — — 130 0 32 120 45 100 1 1 8.50 7.50 Delavan B 60° 60° 209 AJ4CC 52.5 1188 RLS100 3.55 4.45 8.00 14 6.0 4 2.2 5.2 — — — 130 0 30 120 35 100 1 1 9.00 9.00 Delavan B 60° 60° 180 AJ4CC 52.5 1288 RLS100 2.60 5.30 7.9 14 6.0 4 2.0 6.0 — — — 130 0 30 120 40 100 1 1 10.00 10.00 Delavan B 60° 60° 180 AJ4CC 52.5 1388 RLS100 3.35 4.65 8.00 14 6.0 9 2.0 6.5 — — — 130 0 30 120 40 100 1 1 11.00 11.00 Delavan B 60° 60° 200 AJ4CC 52.5 1488 RLS130 2.81 4.54 7.35 14 6.0 6 2.0 6.0 — — — 130 0 40 120 55 100 1 1 12.00 12.00 Delavan B 60° 60° 200 AJ4CC 52.5 1588 RLS130 2.99 4.65 7.64 14 5.5 7 2.5 7.0 — — — 130 0 40 120 30 100 1 1 12.00 12.00 Delavan B 60° 60° 220 AJ4CC 52.5 1688R RLS130 3.40 4.85 8.25 14 5.0 8 2.5 8.0 — — — 130 0 40 120 30 100 1 1 13.00 12.50 Delavan B 60° 60° 215 AJ4CC 52.5 1688 RLS130 3.40 5.10 8.5 14 5.0 9 2.0 9.0 — — — 130 0 50 120 30 100 1 1 13.00 13.00 Delavan B 60° 60° 215 AJ4CC 52.5 Notes for Table 1, Table 2 and Table 3 1. Burner capacities listed for elevations up to 2,000 feet. For higher elevations, consult local Weil-McLain distributor/ agent or sales office. 2. Light oil ratings based on No. 2 fuel oil with heating value of 140,000 Btu per gallon. 3. Gas ratings based on natural gas with heating value of 1,000 Btu per cubic foot and specific gravity of 0.60. Gas burners for other gases are available. Consult local Weil-McLain distributor/agent or sales office. 4. Boiler-burner unit to be adjusted to achieve +0.10 inches W.C. pressure at the flue collar, resulting in positive pressure in firebox as listed. 5. Minimum gas pressures listed are subject to variations due to job conditions. Gas burners for other gas pressures are available. Consult local Weil-McLain distributor/agent or sales office. 6. All gas train sizes shown are based on a supply pressure to the regulator of 7 inches w.c. Optional trains available for other pressures upon request. 7. All Settings and pressures shown are for initial start-up. Final values should be confirmed with combustion analysis. 8. Gas/Light Oil control Systems: • LHL: Low-high-low-off firing conditions - two position air and fuel controlled by separate motor, open damper pre-purge. • MOD: On-off operation with proven low fire start and full modulating firing conditions. Proportional motor drives fuel metering valve and combustion air damper according to firing conditions; open damper pre-purge. 9. 120/60/1 control circuit is used for all burners. 10. All 3 phase models require a separate 12/60/1 control voltage supply. 11. Burner settings shown are for initial start-up. Follow burner manual to adjust burner using combustion test instruments as directed. 12. 120/60/1 control c...


Напишите ваш отзыв об устройстве



Текст отзыва
Ваше имя:
Введите две цифры:
capcha





Категории