Производитель: Maxon Telecom
Размер: 232.96 kb
Название файла:
|
Фрагмент инструкции
© 2008 Copyright Maxon Corporation. All rights reserved. 1-2.3-15 Low temperature burners -INDITHERM® E-m-7/08 Spark ignitor - SI-1/2 The spark ignitor is standard included with the burner. It is advised to keep at least one additional spark ignitor available as a spare item for maintenance. This spark ignitor can be mounted directly onto the burner spark ignitor connection port. To be used on all burner sizes. See table below for mounting position C depending on burner size. 1) 1/2” NPT Dimensions in mm unless stated otherwise burner size A B C D O E 100 165 140 33 5 14 300 165 140 37 5 14 550-850 165 140 31 5 14 1100-1800 165 140 33 5 14 Filter Elements - FLT- INDI Replacement elements for the optional INDITHERM® burners combustion air filters. Available in 4 types to cover all burner sizes. • FLT-INDI-1 for burner sizes 100 and 300 • FLT-INDI-2 for burner size 550 • FLT-INDI-3 for burner sizes 700-850-1100-1500 • FLT-INDI-4 for burner size 1800 .com combustion systems for industry MAXON reserves the right to alter specifications and data without prior notice. © 2008 Copyright Maxon Corporation. All rights reserved. 1-2.3-16 Low temperature burners -INDITHERM® E-m-7/08 Gaskets - GSK- INDI These gaskets are used to seal the mounting plate of the burner and the duct wall. Optionally available in 2 different types: • GSK-INDI-STD to be used in combination with standard discharge sleeves (square) • GSK-INDI-HT to be used in combination with high temperature discharge sleeves (round) Gasket type Burner Type Geometry GSK-INDI-STD-1 100 square GSK-INDI-STD-2 300 square GSK-INDI-STD-3 550-850 square GSK-INDI-STD-4 1100-1800 square GSK-INDI-HT-1 100 round GSK-INDI-HT-2 300 round GSK-INDI-HT-3 550-850 round GSK-INDI-HT-4 1100-1800 round .com combustion systems for industry MAXON reserves the right to alter specifications and data without prior notice. © 2008 Copyright Maxon Corporation. All rights reserved. 1-2.3-17 Low temperature burners -INDITHERM® E-m-7/08 Installation and operation instructions for INDITHERM® burners Application requirements Supporting burner air and gas piping The INDITHERM® burner shall not be used as support for the piping to the burner. Gas and air piping shall be supported in such a way that no additional loads will be created on the burner. Burner mounting flange loads Check burner weight and reinforce burner mounting flange or combustion chamber/furnace back wall if necessary to support the complete burner weight. Installation instructions Storage of INDITHERM® burners INDITHERM® burners shall be stored dry (inside). Burner blocks have been cured carefully before shipment and shall be kept dry. Wetting of the blocks could result in premature failures. Handling of INDITHERM® burners INDITHERM® burners are shipped as complete units. Handle burners with care, using proper equipment during unpacking, transport, lifting and installation. Any impact on the burner could result in damage. To prevent damage in transit, accessories such as flame rods, control valves, UV-scanners, may be packed separately and shipped loose. Orientation of INDITHERM® burners INDITHERM® burners can be mounted and fired in any direction. However...
Эта инструкция также подходит к моделям:Грили - INDITHERM 100 (232.96 kb)
Грили - INDITHERM 850 (232.96 kb)
Грили - INDITHERM 1100 (232.96 kb)
Грили - INDITHERM 1500 (232.96 kb)