|
Фрагмент инструкции
USE OF ANY OTHER PARTS COULD CAUSE INJURY OR DEATH. 14015-1-0903 Page 15 Page 16 14015-1-0903 Parts can be ordered only through your service person or dealer. For best results, the service person or dealer should order parts through the distributor. Parts can be shipped directly to the service person/dealer. All parts listed in the Parts List have a Part Number. When ordering parts, first obtain the Model Number from the name plate on your equipment. Then determine the Part Number (not the Index Number) and the Description of each part from the following appropriate illustration and list. Be sure to give all this information . . . Applaince Model Number Part Description Appliance Serial Number Part Number Type of Gas (Propane or Natural) Do not order bolts, screws, washers or nuts. They are standard hardware items and can be purchased at any local hardware store. Shipments contingent upon strikes, fires and all causes beyond our control. Empire Comfort Systems, Inc. Nine Eighteen Freeburg Ave. Belleville, Illinois 62222-0529 HOW TO ORDER REPAIR PARTS PARTS VIEW PROPANE (LP) GAS CONVERSION INSTRUCTIONS 1. If applicable, turn OFF gas supply to vented decorative log set. 2. If applicable, remove gas supply line from vented decorative log set. 3. For VSM-(18, 24, 30) only,remove Natural gas inlet regulator from burner assembly. 3. For VSR-(18, 24, 30) only, remove regulator cap and blue conversion screw from HI-LO knob on gas valve. 4. For VSM-(18, 24, 30) only, install Propane (LP) gas inlet regulator marked 10.0 onto burner assembly. 4. For VSR-(18, 24, 30) only, install Propane (LP) gas pink conversion screw into HI-LO knob on gas valve. Assure that conversion screw is finger tight (refer to Honeywell conversion instructions which are included in conversion kit). Install new regulator cap over pink conversion screw. 5. Remove Natural gas main burner orifice from orifice fitting. Save the Natural gas main burner orifice from the appliance for future use. Attention: Use appropriate main burner orifice for NORMAL input or REDUCED input. 6. Install Propane (LP) gas main burner orifice into orifice fitting for NORMAL input. For VSM-18 or VSR-18, install one Propane (LP) gas main burner orifice marked 41 for 65,000 BTUH input. For VSM-24 or VSR-24, install one Propane (LP) gas main burner orifice marked 40 for 75,000 BTUH input. For VSM-30 or VSR-30, install one Propane (LP) gas main burner orifice marked 40 for 75,000 BTUH input. 6. Install Propane (LP) gas main burner orifice into orifice fitting for REDUCED input. For VSM-18 or VSR-18, install one Propane (LP) gas main burner orifice marked 49 for 40,000 BTUH input. For VSM-24 or VSR-24, install one Propane (LP) gas main burner orifice marked 45 for 50,000 BTUH input. For VSM-30 or VSR-30, install one Propane (LP) gas main burner orifice marked 43 for 60,000 BTUH input. 7. Remove pilot tubing from pilot burner. 8. Remove Natural gas pilot orifice from pilot burner. Save the Natural gas pilot orifice removed from the appliance for future use. 9. Insert Propane (LP) gas pilot orifice marked 8 into pilot burner. 10. Attach pilot tubing into pilot burner. 11. Connect gas supply line to vented decorative log set. 12. Attach R-1322, conversion label and R-1321, gas conversion label to the 4 3/4" x 7 1/4" metal plate supplied in conversion kit. Attach 4 3/4" x 7 1/4" metal plate to metal chain which is attached to base assembly. 13. Pressure Testing of the Gas Supply System a. To check the inlet pressure to the gas valve, a 1/8" (3mm) N.P.T. plugged tapping, accessible for test gauge connection, must be placed immediately upstream of the gas supply connection to the appliance. b. The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa). c. The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa). Attention! If one of the above procedures results in pressures in excess of 1/2 psig (14" w.c.) (3.5 kPa) on the appliance gas valve, it will result in a hazardous condition. 14. Turn on Propane (LP) gas supply to vented decorative log set. 15. All gas connections must be checked for gas leaks by the person (qualified agency) making the gas conversion. This should be done with a soap solution watching for bubbles on all exposed connections, and if unexposed, a pressure test must be done. 16. Check the appropriate manifold pressure for the vented decorative log set according to Gas Supply on Page 8 in this manual. 17. Check pilot burner flame pattern according to Pilot and Main Burner Flame Characteristics on Page 12 in this manual. 18. Check main burner flame pattern according to Pilot and Main Burner Flame Characteristics on Page 12 in this manual. 19. Gas conversion i...
Эта инструкция также подходит к моделям:Грили - VSM-18-1 (1.04 mb)
Грили - VSM-24-1 (1.04 mb)
Грили - VSM-30-1 (1.04 mb)
Грили - VSR-18-1 (1.04 mb)